Randomized comparison of closed-loop feedback computer-controlled with manual-controlled infusion of phenylephrine for maintaining arterial pressure during spinal anaesthesia for caesarean delivery.

نویسندگان

  • W D Ngan Kee
  • K S Khaw
  • F F Ng
  • Y H Tam
چکیده

BACKGROUND Closed-loop feedback computer-controlled infusion has not been described for administering phenylephrine to maintain arterial pressure (AP) during spinal anaesthesia for caesarean delivery. We aimed to compare AP control using this automated system with a previously described manual infusion system. METHODS We randomly allocated 222 healthy subjects having spinal anaesthesia for scheduled caesarean delivery to have systolic AP maintained near baseline with phenylephrine (100 µg ml(-1)) by computer-controlled infusion utilizing a proportional algorithm or manual-controlled infusion utilizing an on-off algorithm. AP control was assessed by comparing the proportion of systolic AP measurements within ±20% of baseline and by performance error (PE) calculations. RESULTS A total of 212 subjects finished the study. In the computer-control group, 97% of systolic AP recordings fell within ±20% of baseline compared with 95% in the manual-control group (P=0.0004). For computer-control compared with manual-control, wobble was smaller [median 3.5 (inter-quartile range 2.5-4.8)% vs 4.2 (3.3-5.9)%, P=0.003], but there was no difference in the median PE [2.9 (0.3-4.7)% vs 1.9 (0-4.2)%], median absolute PE [4.7 (3.5-5.6)% vs 4.7 (3.8-6.7)%], or divergence [-0.01 (-0.03-0)% vs -0.06 (-0.26-0.08)%]. Fewer interventions per subject for controlling AP were required in the computer-control group [2 (2-2) vs 10 (8-13), P<0.001]. There were no differences in measured clinical outcomes. CONCLUSIONS Within the constraints of the studied algorithms, closed-loop feedback computer-controlled phenylephrine infusion provided better AP control with fewer interventions required compared with manual-controlled infusion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Prophylactic Infusion of Phenylephrine with Ephedrine for Prevention of Hypotension in Elective Cesarean Section under Spinal Anesthesi: A Randomized Clinical Trial

Background: Spinal anesthesia is an accepted technique in elective cesarean sections. However, hypotension, resulted from sympathectomy is a common problem, especially in pregnant women. Prevention of this complication by sympathomimetic agents is of potential clinical significance. The aim of this study is to compare the effect of prophylactic infusion of Phenylephrine versus Ephedrine in the ...

متن کامل

Comparison between two phenylephrine infusion rates with moderate co-loading for the prevention of spinal anaeshtesia-induced hypotension during elective caesarean section.

BACKGROUND Phenylephrine induces maternal bradycardia in 50% of mothers when used for prevention and treatment of spinal anaesthesia-induced hypotension during caesarean delivery. Rapid fluid administration immediately after initiation of the spinal block (co-loading) may have a vasopressor sparing effect. The aim of this study was to evaluate the hypothesis that when using rapid crystalloid co...

متن کامل

A randomised controlled trial comparing weight adjusted dose versus fixed dose prophylactic phenylephrine infusion on maintaining systolic blood pressure during caesarean section under spinal anaesthesia.

BACKGROUND Spinal anaesthesia is the standard of care for elective caesarean delivery. It has advantages over general anaesthesia. However the sympathetic blockade induced by spinal anaesthesia results in an 80 percent incidence of hypotension without prophylactic management. Current evidence supports co-loading with intravenous fluids in conjunction with the use of vasopressors as the most eff...

متن کامل

Randomized double-blinded comparison of norepinephrine and phenylephrine for maintenance of blood pressure during spinal anesthesia for cesarean delivery.

BACKGROUND During spinal anesthesia for cesarean delivery, phenylephrine can cause reflexive decreases in maternal heart rate and cardiac output. Norepinephrine has weak β-adrenergic receptor agonist activity in addition to potent α-adrenergic receptor activity and therefore may be suitable for maintaining blood pressure with less negative effects on heart rate and cardiac output compared with ...

متن کامل

Evaluation of closed loop control of arterial pressure during hypotensive anaesthesia for local resection of intraocular melanoma.

We have studied 20 patients undergoing local resection of intraocular melanoma during hypotensive anaesthesia, allocated randomly to receive either manual control by an experienced anaesthetist or closed-loop computer control of an infusion of a 5:1 mixture of trimetaphan camsylate (TMP) and sodium nitroprusside (SNP). There were no significant differences in the smallest systolic and diastolic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 110 1  شماره 

صفحات  -