What is the learning curve for robotic-assisted pedicle screw placement in spine surgery?
نویسندگان
چکیده
BACKGROUND Some early studies with robotic-assisted pedicle screw implantation have suggested these systems increase accuracy of screw placement. However, the relationship between the success rate of screw placement and the learning curve of this new technique has not been evaluated. QUESTIONS/PURPOSES We determined whether, as a function of surgeon experience, (1) the success rate of robotic-assisted pedicle screw placement improved, (2) the frequency of conversion from robotic to manual screw placement decreased, and (3) the frequency of malpositioned screws decreased. METHODS Between June 2010 and August 2012, the senior surgeon (IHL) performed 174 posterior spinal procedures using pedicle screws, 162 of which were attempted with robotic assistance. The use of the robotic system was aborted in 12 of the 162 procedures due to technical issues (registration failure, software crash, etc). The robotic system was successfully used in the remaining 150 procedures. These were the first procedures performed with the robot by the senior surgeon, and in this study, we divided the early learning curve into five groups: Group 1 (Patients 1-30), Group 2 (Patients 31-60), Group 3 (Patients 61-90), Group 4 (Patients 91-120), and Group 5 (Patients 121-150). One hundred twelve patients (75%) had spinal deformity and 80 patients (53%) had previous spine surgery. The accuracy of screw placement in the groups was assessed based on intraoperative biplanar fluoroscopy and postoperative radiographs. The results from these five groups were compared to determine the effect on the learning curve. The numbers of attempted pedicle screw placements were 359, 312, 349, 359, and 320 in Groups 1 to 5, respectively. RESULTS The rates of successfully placed screws using robotic guidance were 82%, 93%, 91%, 95%, and 93% in Groups 1 to 5. The rates of screws converted to manual placement were 17%, 7%, 8%, 4%, and 7%. Of the robotically placed screws, the screw malposition rates were 0.8%, 0.3%, 1.4%, 0.8%, and 0%. CONCLUSIONS The rate of successfully placed pedicle screws improved with increasing experience. The rate of the screws that were converted to manual placement decreased with increasing experience. The frequency of screw malposition was similar over the learning curve at 0% to 1.4%. Future studies will need to determine whether this finding is generalizable to others. LEVEL OF EVIDENCE Level III, therapeutic study. See the Instructions for Authors for a complete description of levels of evidence.
منابع مشابه
Accuracy of computer-assisted pedicle screw placement. An in vivo computed tomography analysis.
STUDY DESIGN A computer-assisted planning and visualization system (the Orthopaedic Surgery Planning System) was tested for pedicle screw insertion in vivo. OBJECTIVES To evaluate the system's applicability for regular intraoperative use and its accuracy for pedicle screw placement in vivo. SUMMARY OF BACKGROUND DATA Pedicle screw placement poses considerable anatomic and biomechanical risk...
متن کاملAssessment of pedicle screw placement accuracy, procedure time, and radiation exposure using a miniature robotic guidance system.
STUDY DESIGN Controlled, cadaveric implantation trial. OBJECTIVE To evaluate the effect of a robotic guidance system on screw placement accuracy, amount of radiation exposure, and length of procedure time during percutaneous pedicle screw implantation. SUMMARY OF BACKGROUND DATA Pedicle screws are associated with low complication rates, and several computer-assisted image guidance systems e...
متن کاملThe surgical learning curve and accuracy of minimally invasive lumbar pedicle screw placement using CT based computer-assisted navigation plus continuous electromyography monitoring – a retrospective review of 627 screws in 150 patients
OBJECTIVE This study retrospectively assessed the accuracy of placement of lumbar pedicle screws placed by a single surgeon using a minimally-invasive, intra-operative CT-based computer navigated technique in combination with continuous electromyography (EMG) monitoring. The rates of incorrectly positioned screws were reviewed in the context of the surgeon's experience and learning curve. MET...
متن کاملA medium invasiveness multi-level patient’s specific template for pedicle screw placement in the scoliosis surgery
BACKGROUND Several methods including free-hand technique, fluoroscopic guidance, image-guided navigation, computer-assisted surgery system, robotic platform and patient's specific templates are being used for pedicle screw placement. These methods have screw misplacements and are not always easy to be applied. Furthermore, it is necessary to expose completely a large portions of the spine in or...
متن کاملAccuracy Assessment of Freehand Pedicular Screw Placement
Background: The purpose of this prospective study was to determine the accuracy of pedicular screw insertion withoutthe use of fluoroscopy.Methods: This study was conducted on patients with spinal diseases in need of pedicular screw fixation and fusion.The included patients suffered from such conditions as vertebral fracture, spinal stenosis, kyphosis, tumor, and pelvicf...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical orthopaedics and related research
دوره 472 6 شماره
صفحات -
تاریخ انتشار 2014