چکیده

A screen printed carbon electrode (SPCE) containing the electrocatalyst Meldola’s Blue (MB) has been investigated as the base transducer for a glutamate biosensor. The sandwich biosensor was fabricated by firstly depositing a chitosan (CHIT) layer onto the surface of the transducer (MB-SPCE), followed by glutamate dehydrogenase (GLDH): this device is designated GLDH-CHIT-MB-SPCE. NAD was added to buffer solutions prior to the measurement of glutamate. This biosensor was used in conjunction with amperometry in stirred solution at an applied potential of +0.1 V (vs. Ag/AgCl). Optimum conditions for the analysis of glutamate were found to be as follows: temperature, 35 °C; buffer, pH 7; ionic strength, 75 mM; NAD, 4 mM; CHIT 0.05% in 0.05 M HCl; GLDH, 30 U. The linear range of the biosensor was found to be 12.5 μM to 150 μM, the calculated limit of detection (based on three times signal to noise) was 1.5 μM and the sensitivity was 0.44 nA/μM. The proposed biosensor was used to measure glutamate in serum before and after fortification with glutamate. The endogenous concentration of glutamate was found to be 1.68 mM and the coefficient of variation (CV) was 4.1%. The serum was then fortified with 2 mM of glutamate, and the resulting mean recovery was 96% with a CV of 3.3% (n=6). An unfiltered beef OXO cube was analysed for monosodium glutamate (MSG) content. The endogenous Analytical & Bioanalytical Electrochemistry © 2014 by CEE www.abechem.com Anal. Bioanal. Electrochem., Vol. 6, No. 4, 2014, 435-449 436 content of MSG was 125.43 mg/g with a CV of 8.98%. The OXO cube solution was fortified with 0.935 g (100 mM) of glutamate, the resulting mean recovery was 91% with a CV of 6.39%. KeywordsGlutamate, Screen-printed biosensor, Amperometry, Clinical, Food

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A new amperometric ß-ODAP biosensor

Introduction The Lathyrus/lathyrism challenge is broad-based by its nature and requires multi-disciplinary efforts of specialists in the field of epidemiology, neurology, biochemistry, chemistry, nutrition, and agronomy. The role of chemists is in systematic determination of minor natural products in L. sativus seeds so that the sole responsibility of ß-ODAP for neurolathyrism is ascertained . ...

متن کامل

A Novel Amperometric Glutamate Biosensor Based on Glutamate Oxidase Adsorbed on Silicalite

In this work, we developed a new amperometric biosensor for glutamate detection using a typical method of glutamate oxidase (GlOx) immobilization via adsorption on silicalite particles. The disc platinum electrode (d = 0.4 mm) was used as the amperometric sensor. The procedure of biosensor preparation was optimized. The main parameters of modifying amperometric transducers with a silicalite lay...

متن کامل

Evaluation of Glutamate Dehydrogenase Activity and Insulin Secretion in Mice Exposed to Dexamethasone

Background and Aims: Diabetes is one of the most important endocrine disrupters and is associated with various hormones, including those that can lead to diabetes. Glucocorticoid use may lead to insulin resistance. Dexamethasone is one of these glucocorticoid compounds. Glutamate dehydrogenase plays a key role in the production of glutamate in the secretion of insulin. Based on these hormonal i...

متن کامل

A probe for NADH and H2O2 amperometric detection at low applied potential for oxidase and dehydrogenase based biosensor applications.

Modified screen-printed electrodes for amperometric detection of H(2)O(2) and nicotinamide adenine dinucleotide (NADH) at low applied potential are presented in this paper. The sensors are obtained by modifying the working electrode surface with Prussian Blue, a well known electrochemical mediator for H(2)O(2) reduction. The coupling of this sensor with phenazine methosulfate (PMS) in the worki...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014