This review considers methods used to quantify lag screw placement within the femoral head following proximal femoral fracture. Implants used for fixation of femoral neck fractures can lead to unwanted outcomes in some patients. Cutting out of the screw within the femoral head has been shown to be the commonest cause of failure and is related to lag screw placement within the femur. Until now, there have been two methods published which quantify lag screw position within the femoral head. These are the concepts of 'Tip Apex Distance' and Parker's ratio method of lag screw placement. We shall discuss each one in turn and their implications in terms of fracture fixation failure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A biomechanical study of conventional acetabular internal fracture fixation versus locking plate fixation.

BACKGROUND Conventional internal fixation entails the use of an interfragmentary lag screw along with a plate. Not all acetabular fractures are amenable to the placement of an interfragmentary lag screw, and the fracture may be displaced during tightening of the interfragmentary lag screw. Locking plates are a possible solution. We sought to determine whether a locking plate construct can provi...

متن کامل

Comparison of Intertrochanteric Fracture Fixation with Dynamic Hip Screw and Bipolar Hemiarthroplasty Techniques

Background: At present, there is no consensus on an appropriate treatment modality for intertrochanteric fractures in the elderly with background diseases. The aim of the present study was to compare treatment outcomes of intertrochanteric fractures reduced with dynamic hip screws (DHS) and bipolar hemiarthroplasty in elderly patients with background medical conditions. Methods: In this randomi...

متن کامل

Medial pelvic migration of the lag screw in a short gamma nail after hip fracture fixation: a case report and review of the literature

Hip fractures are a common injury among the elderly. Internal fixation with an intramedullary (IM) system has gained popularity for the treatment of intertrochanteric femur fractures. Multiple complications associated with IM fracture fixation have been described, however, we report a rare complication of medial pelvic migration of the lag screw of a short IM nail in a stable construct ten week...

متن کامل

Isolated Buttress Plating of Posterior Wall Acetabular Fractures: Is it Sufficient?

Background: Conventional fixation methods of posterior wall acetabular fractures feature the use of plating and lagscrews. However, fixation of posterior wall fractures with buttress plating alone offers potential advantages by avoidingthe hardware complications related to hardware placement through the wall fragment. The purpose of this study wasto examine if buttress plating...

متن کامل

بررسی کاربرد Short barrel DHS در درمان شکستگی انترتروکانتریک

Cut out or extrusion of the lag screw from the superior aspect of head and neck of the femur is one of the most common and devastating complications of the surgery of the intertrochanteric fractures with DHS. The exact cause of this complications is unknown, but it seems to be related to osteopenia, inappropriate position of lag screw inside head of the femur and inability of DHS to slide insid...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta orthopaedica Belgica

دوره 71 3  شماره 

صفحات  -

تاریخ انتشار 2005