This study evaluated the effect of microwave energy on the hardness, impact strength and flexural strength of the Clássico, Onda-Cryl and QC-20 acrylic resins. Aluminum die were embedded in metallic or plastic flasks with type III dental stone, in accordance with the traditional packing technique. A mixing powder/liquid ratio was used according to the manufacturer's instructions. After polymerization in water batch at 74 degrees C for 9 h, boiling water for 20 min or microwave energy at 900 W for 10 min, the specimens were deflasked after flask cooling at room temperature, and submitted to finishing. Specimens non-disinfected and disinfected by microwave irradiation were submitted to hardness, impact and flexural strength tests. Each specimen was immersed in distilled water and disinfected in a microwave oven calibrated to 650 W for 3 min. Knoop hardness test was performed with 25 g load for 10 s, impact test was carried out using the Charpy system with 40 kpcm, and 3-point bending test with a crosshead speed of 0.5 mm/min until fracture. Data were submitted to statistical analysis by ANOVA and Tukey's test (alpha=0.05). Disinfection by microwave energy decreased the hardness of Clássico and Onda-Cryl acrylic resins, but no effect was observed on the impact and flexural strength of all tested resins.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of simulated microwave disinfection on the mechanical properties of three different types of denture base resins.

STATEMENT OF PROBLEM Disinfection of prostheses with chemical solutions has deleterious effects on dentures. The appropriate power setting of microwave for disinfection, without affecting denture base properties, is a controversy. PURPOSE To evaluate and compare the effect of simulated microwave disinfection at a recommended power setting on the mechanical properties of three denture base hea...

متن کامل

Effect of repeated disinfections by microwave energy on the physical and mechanical properties of denture base acrylic resins.

The present study evaluated the effect of repeated simulated microwave disinfection on physical and mechanical properties of Clássico, Onda-Cryl and QC-20 denture base acrylic resins. Aluminum patterns were included in metallic or plastic flasks with dental stone following the traditional packing method. The powder/liquid mixing ratio was established according to the manufacturer's instructions...

متن کامل

A comparison of the impact strength between Acropars and Meliodent acrylic resins

A comparison of the impact strength between Acropars and Meliodent acrylic resins Dr. F. Golbidi* - Dr. A. Meghdadi** *-Assistant Professor of Prosthodontics Dept. – Faculty of Dentistry – Isfahan University of Medical Sciences. **-Dentist. Background and Aim: One of the mostly used materials in removable prostheses are acrylic resins with various physical and mechanical properties. The impact ...

متن کامل

The Effect of Repeated Microwaving Disinfection on the Dimensional Stability of Acrylic Dentures.

OBJECTIVE The aim of this study was to evaluate the effect of repeated microwave disinfections on the dimensional stability of acrylic dentures. MATERIALS AND METHODS Three groups of dentures made of a heat polymerized acrylic resin were tested. I: dentures kept in water (control group). II: dentures microwaved daily while being immersed into water (wet disinfection). III: dentures microwaved...

متن کامل

Effect of Storage Conditions and Disinfection with 2% Deconex® on Dimensional Stability of Two Self-Cure Acrylic Resins

Background and Aim: There is a gap of information on the effect of time, disinfectant, and storage conditions on the dimensional stability of direct post patterns made of self-cure acrylic resins. This study assessed the effect of Deconex® and wet or dry stor-age conditions on the dimensional stability of post patterns made of Duralay and GC acrylic resins. Materials and Methods: Sixty spe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Brazilian dental journal

دوره 19 4  شماره 

صفحات  -

تاریخ انتشار 2008