Accuracy and limits of transpulmonary dilution methods in estimating extravascular lung water after pneumonectomy.

نویسندگان

  • Antoine Roch
  • Pierre Michelet
  • Benoit D'journo
  • Denis Brousse
  • Dorothee Blayac
  • Dominique Lambert
  • Jean-Pierre Auffray
چکیده

STUDY OBJECTIVES The measurement of extravascular lung water index by double indicator (EVLWIdi) or the measurement of extravascular lung water index by transpulmonary thermodilution (EVLWItt) could be useful after pneumonectomy. Since pulmonary blood flow and volume are altered after pneumonectomy, the validity of these methods is uncertain. This study has compared measurements of EVLWIdi and EVLWItt with measurement of extravascular lung water index by gravimetry (EVLWIg) in a porcine model of pulmonary edema induced after right pneumonectomy. DESIGN Randomized laboratory study. SETTING Animal research laboratory. SUBJECTS Twenty-seven female pigs; mean weight, 35 +/- 5 kg (+/- SD). INTERVENTIONS The pigs were anesthetized, placed on mechanical ventilation, and allocated to a two-lung group (n = 10) or a right pneumonectomy group (n = 17). EVLWIdi and EVLWItt were measured at baseline, 60 min after pneumonectomy, and 60 min after IV injection of oleic acid (OA). MEASUREMENTS AND RESULTS There was a good correlation between EVLWIg and EVLWIdi values (r = 0.96, p < 0.0001 in the two-lung group; and r = 0.81, p = 0.02 in the pneumonectomy group). EVLWIdi underestimated EVLWIg in the two-lung group (- 3 mL/kg; 95% confidence interval [CI], - 7 to + 2 mL/kg) and in the pneumonectomy group (- 0.9 mL/kg; 95% CI, - 3.3 to + 1.5 mL/kg). After pneumonectomy, EVLWItt decreased in mean by 27% and increased in mean by 70% after OA acid. There was a good correlation between EVLWIg and EVLWItt values (r = 0.96, p < 0.0001 in the two-lung group; and r = 0.90, p < 0.0001 after pneumonectomy). EVLWItt slightly overestimated gravimetric value in the two-lung group (+ 1.5 mL/kg; 95% CI, - 1.5 to + 4.2 mL/kg) and largely overestimated gravimetric value after pneumonectomy (+ 5 mL/kg; 95% CI, + 3.4 to + 6.8 mL/kg). CONCLUSION Double-indicator and transpulmonary thermodilution methods could be useful in monitoring extravascular lung water index (EVLWI) after pneumonectomy, but transpulmonary thermodilution largely overestimates EVLWI.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Extravascular Lung Water and Acute Lung Injury

Acute lung injury carries a high burden of morbidity and mortality and is characterised by nonhydrostatic pulmonary oedema. The aim of this paper is to highlight the role of accurate quantification of extravascular lung water in diagnosis, management, and prognosis in "acute lung injury" and "acute respiratory distress syndrome". Several studies have verified the accuracy of both the single and...

متن کامل

Estimation of errors in determining intrathoracic blood volume using the single transpulmonary thermal dilution technique in hypovolemic shock.

BACKGROUND The transpulmonary thermal dilution technique has been widely adopted for monitoring cardiac preload and extravascular lung water in critically ill patients. This method assumes intrathoracic blood volume (ITBV) to be a fixed proportion of global end-diastolic volume (GEDV). This study determines the relation between GEDV and ITBV under normovolemic and hypovolemic conditions and qua...

متن کامل

Lung water and urea indicator dilution studies in cardiac surgery patients. Comparisons of measurements in aortocoronary bypass and mitral valve replacement.

We measured transpulmonary indicator dilution curves of 51Cr-erythrocytes, 125I-albumin, 14C-urea, and 3H-water before and six and 24 hours after operation in seven patients undergoing aortocoronary bypass (ACB) and eight patients undergoing mitral valve replacement (MVR). We calculated cardiac output (CO), extravascular lung water (EVLW), the difference between 125I-albumin and 51Cr-erythrocyt...

متن کامل

Assessment of cardiac output with transpulmonary thermodilution during exercise in humans.

The accuracy and reproducibility of transpulmonary thermodilution (TPTd) to assess cardiac output (Q̇) in exercising men was determined using indocyanine green (ICG) dilution as a reference method. TPTd has been utilized for the assessment of Q̇ and preload indexes of global end-diastolic volume and intrathoracic blood volume, as well as extravascular lung water (EVLW) in resting humans. It remai...

متن کامل

Acute lung injury, overhydration or both?

Acute lung injury or acute respiratory distress syndrome (ALI/ARDS) in the course of sepsis is thought to result from increased pulmonary capillary permeability and resultant edema. However, when the edema is assessed at the bedside by measuring the extravascular thermal volume by transpulmonary dilution, some ALI/ARDS patients with sepsis may have normal extravascular lung water (EVLW). Conver...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 128 2  شماره 

صفحات  -

تاریخ انتشار 2005