Does "hidden undercuffing" occur among obese patients? Effect of arm sizes and other predictors of the difference between wrist and upper arm blood pressures.

نویسندگان

  • Hardik Doshi
  • Alan B Weder
  • Robert L Bard
  • Robert D Brook
چکیده

Arm size can affect the accuracy of blood pressure (BP) measurement, and "undercuffing" of large upper arms is likely to be a growing problem. Therefore, the authors investigated the relationship between upper arm and wrist readings. Upper arm and wrist circumferences and BP were measured in 261 consecutive patients. Upper arm auscultation and wrist BP was measured in triplicate, rotating measurements every 30 seconds between sites. Upper arm BP was 131.9+/-20.6/71.6+/-12.6 mm Hg in an obese population (body mass index, 30.6+/-6.6 kg/m(2)) with mean upper arm size of 30.7+/-5.1 cm. Wrist BP was higher (2.6+/-9.2 mm Hg and 4.9+/-6.6 mm Hg, respectively, P<.001); however, there was moderate concordance for the Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure (JNC 7) strata (kappa value=0.27-0.71), and the difference was >or=5 mm Hg in 72% of the patients. The authors conclude that there was poor concordance between arm and wrist BP measurement and found no evidence that "hidden undercuffing" was associated with obesity; therefore, they do not support routine use of wrist BP measurements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of blood pressure measurements on the upper and lower extremities during spinal anesthesia

Introduction: During spinal anesthesia, measurement of blood pressure is often obtained by an indirect method using an inflatable cuff on the upper arm. The relationship between the blood pressure measurements at the two sites in patients undergoing spinal anesthesia is unclear. This study was designed to evaluate the difference observed in systolic blood pressure (SBP) taken from the upp...

متن کامل

Initial Effect of Taping Technique on Wrist Extension and Grip Strength and Pain of Individuals with Lateral Epicondylitis

Objectives: Aim of this study is to investigate the initial effect of taping technique on wrist extension and grip strength and pain of Individuals with tennis elbow. Methods: fifteen patients (10 men and 5 women with 42.53 years) on their dominant arm participated in this study. Outcome measures were wrist extension and grip strength and pain taken before and immediately after application o...

متن کامل

A comparison of noninvasive blood pressure measurement on the wrist with invasive arterial blood pressure monitoring in patients undergoing bariatric surgery.

BACKGROUND In morbidly obese patients, oscillometric blood pressure measurements with an upper-arm cuff are often difficult to perform. The alternative method, invasive blood pressure monitoring, can be difficult to place and is associated with risks. A wrist-mounted blood pressure-monitoring device, the Vasotrac, provides accurate blood pressure measurements in lean patients. Even in the obese...

متن کامل

Effect of Resisted Bimanual Therapy With Auditory Cues on Arm Function, Balance, and Endurance in Stroke Survivors: A Pilot Study

Objectives: Upper limb motor impairment causes limited activities of daily living in stroke survivors. Bimanual therapy is based on Bimanual movement that facilitates cortical balancing by simultaneous movement of paretic and non-paretic arms while performing a task. Studies aimed at exploring the effects of resisted Bimanual therapy with rhythmic auditory cues on arm function, balance, and end...

متن کامل

Measuring blood pressure at the wrist: more comfortable for patients and more convenient for doctors?

OBJECTIVES To compare the agreement between conventional measurement of blood pressure and measurements obtained using two automated devices; and to compare how comfortable each of the three methods of measurement were for patients. METHODS Blood pressure measurements and patient comfort scores were recorded using three different devices in 125-surgery and 40-community patients. The devices u...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical hypertension

دوره 12 2  شماره 

صفحات  -

تاریخ انتشار 2010