Magnetization transfer or spin-lock? An investigation of off-resonance saturation pulse imaging with varying frequency offsets.
نویسندگان
چکیده
PURPOSE To characterize near-resonance saturation pulse MR imaging on a 1.5-T scanner in order to gain insight into underlying mechanisms that alter tissue contrast and to optimize the technique for neuroimaging. METHODS Off-resonance saturation pulses were applied to T1-weighted, spin-density-weighted, and T2-weighted sequences at frequency offsets ranging from 50 Hz to 20,000 Hz down field from water resonance. Suppression ratios were determined at each offset for phantom materials (MnCl2 solution, gadopentetate dimeglumine, corn oil, water, and agar), normal brain structures, and a variety of brain lesions. RESULTS Signal suppression of MnCl2 on T1-weighted images occurred at offsets of less than 2000 Hz even though no macromolecules were present in the solution. Only those phantom materials and tissues with short or intermediate T1 relaxation times and relatively large T1/T2 ratios were sensitive to changing frequency offsets. Suppression of brain increased from approximately 20% at 2000 Hz offset to approximately 45% when the offset was reduced to 300 Hz. In human subjects, the net effect of reducing the frequency offset was to increase T2 contrast on T1-weighted, spin-density-weighted, and T2-weighted images. Distilled water and contrast material did not suppress except at very low offsets ( < 300 Hz). A frequency offset of 300 Hz was optimal for maximizing conspicuity between most contrast-enhancing lesions and adjacent brain while preserving anatomic detail. CONCLUSION Suppression of MnCl2 indicates that magnetization transfer is not the sole mechanism of contrast in near-resonance saturation MR imaging. Spin-lock excitation can reasonably explain the behavior of the phantom solutions and the increase in T2 contrast of tissues achieved as the frequency offset is decreased from 2000 Hz to 300 Hz. Below 300 Hz, saturation is presumably caused by spin-tip effects. With our pulse design, an offset of 300 Hz is optimal for many routine clinical imaging examinations.
منابع مشابه
Near-resonance saturation pulse imaging of the extraocular muscles in thyroid-related ophthalmopathy.
PURPOSE We examined the utility of near-resonance saturation pulse imaging (magnetization transfer [MT] and spin lock) in characterizing microstructural changes occurring in the extraocular muscles of patients with thyroid-related ophthalmopathy (TRO). METHODS Eight healthy volunteers and 10 patients with TRO were imaged using an off-resonance saturation pulse in conjunction with conventional...
متن کاملAnalytical determination of the chemical exchange saturation transfer (CEST) contrast in molecular magnetic resonance imaging
Magnetic resonance based on molecular imaging allows tracing contrast agents thereby facilitating early diagnosis of diseases in a non-invasive fashion that enhances the soft tissue with high spatial resolution. Recently, the exchange of protons between the contrast agent and water, known as the chemical exchange saturation transfer (CEST) effect, has been measured by applying a suitable pulse ...
متن کاملSpin lock and magnetization transfer imaging of head and neck tumors.
PURPOSE To evaluate and compare the spin lock and magnetization transfer techniques in the differentiation of benign and malignant head and neck tumors at magnetic resonance (MR) imaging. MATERIALS AND METHODS Forty consecutive patients with histologically verified head and neck tumors (20 malignant and 20 benign tumors, including five infections) were studied with a 0.1-T MR unit. The spin l...
متن کاملiDQC MR Imaging with Contrast of Off-resonance Rotating-frame Spin-Lattice Relaxation
Methods In Fig. 1, the low-power rf pulse (ω1)y and frequency offset ∆ω constitute an effective spin-locking field along the z′ axis of a tilted rotating frame, with an effective frequency 2 2 1 ( ) e ω ω ω = + ∆ and a tilt angle θ = arctan(ω1/∆ω) with respect to the normal Larmor rotating frame (θ = π/2 for an on-resonance spin-locking pulse without frequency offset) [1,2]. The magnetization a...
متن کاملSpin-locking versus chemical exchange saturation transfer MRI for investigating chemical exchange process between water and labile metabolite protons.
Chemical exchange saturation transfer (CEST) and spin-locking (SL) experiments were both able to probe the exchange process between protons of nonequivalent chemical environments. To compare the characteristics of the CEST and SL approaches in the study of chemical exchange effects, we performed CEST and SL experiments at varied pH and concentrated metabolite phantoms with exchangeable amide, a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 17 5 شماره
صفحات -
تاریخ انتشار 1996