Can electrocardiogram electrodes replace bispectral index electrodes for monitoring depth of anesthesia?

نویسندگان

  • Phuping Akavipat
  • Kasinee Dumrongbul
  • Pattama Neamnak
چکیده

BACKGROUND Bispectral index has been introduced to provide optimal level of anesthesia. However, Bispectral index monitoring may not be cost effective in a relatively short procedures due to the high costs of the electrode. The authors conducted the present study to compare the feasibility of commercially available electrocardiogram (ECG) electrodes instead of the Bispectral index (BIS) monitoring. MATERIAL AND METHOD The authors evaluated the difference in signal quality index (SQI) and BIS values collected from two BIS monitors, using ECG electrodes and BIS electrodes on the same patients before anesthesia, during light anesthesia, deep anesthesia and the emergence period Both sets of electrodes were placed at bifrontal areas throughout the procedure. Statistical analysis was evaluated by mean difference 95% confidence limits of agreement and visualized by Bland-Altman plot. A parametric analysis was analyzed using paired t-test. RESULTS There were 390 parallel signal quality index and BIS values recorded in the present study. During anesthesia the mean BIS values were 58.63 +/- 18.77 in the ECG electrode group and 56.99 +/- 19.84 in the BIS electrode group, which were not statistically different. The mean SQI values were 79.2 +/- 24.8 and 82.8 +/- 21.6 using ECG electrodes and BIS electrodes, respectively. The mean difference between BIS values was 1.65 with 95% confidence limits of agreement between 0.91 and 2.38. CONCLUSION Commercial ECG electrodes could be used for monitoring depth of anesthesia with clinically acceptable mean bias and 95% confidence limits of agreement of BIS value obtained from BIS electrode.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Alternative placement of bispectral index electrode for monitoring depth of anesthesia during neurosurgery.

In neurosurgery in particular, the recommended placement of electrodes for monitoring depth of anesthesia during surgery sometimes conflicts with the surgical site or patient positioning. Therefore, we proposed this study to evaluate the agreement and correlation of bispectral index values recorded from the usual frontal area and the alternate, post-auricular areas in neurosurgery patients. Thi...

متن کامل

Impact of Bispectral Index Monitoring Versus Clinical Judgment as a Guide for Conduction of Anesthesia on Serum Cortisol Level in Co-ronary Artery Bypass Graft Surgery

Background: Inadequate depth of anesthesia leads to release of stress hormones. Electroencephalographic monitoring by bispectral index is a guide to asses the depth of anesthesia. The aim of the present study was to measure the serum cortisol levels as an index of stress response in patients who are candidates for coronary artery bypass graft surgery in two groups of patients. Methods: Seventy-...

متن کامل

Evaluation of the Adequacy of General Anesthesia in Cesarean Section by Bispectral Index

Background: Awareness and recall, though not common, are the major hazards of general anesthesia, especially in Cesarean section (C/S) because of the absence of benzodiazepine and opioids for a significant time during anesthesia. In this study, the Bispectral Index (BIS), end-tidal isoflurane, and hemodynamic parameters were examined to evaluate the depth of the routine general anesthetic techn...

متن کامل

بررسی مقایسه‌ای انفوزیون مداوم رمی‌فنتانیل و پاراستامول بر میزان عمق بیهوشی با مونیتورینگ BIS در اعمال جراحی اندوسکوپی سینوس

    Background & Aim: Paracetamol is a non-opioid and non-NSAID(non non-steroidal anti-inflammatory drug) analgesic with central function. Analgesic effect of paracetamol is similar to opioids and NSAIDs but different from them in terms of side effects. Remifentanil is a short-acting opioid. In our study, we assess the effect of these two drugs on the depth of anesthesia using BIS monitoring. B...

متن کامل

Comparative Evaluation of the Cerebral State Index Tm and Bispectral Index Tm Monitoring during Propofol -remifentanil Anesthesia for Open Heart Surgery

Objective: The Cerebral State index (CSI) is a new index based on electroencephalogram to monitor depth of anesthesia. Transferring guidelines for titration of the Bispectral index (BIS) to the CSI depends on their compatibility. We compared the relationship between BIS and CSI values during propofol-remifentanil anesthesia. Methods: Forty one adult patients about to have open heart surgeries w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the Medical Association of Thailand = Chotmaihet thangphaet

دوره 89 1  شماره 

صفحات  -

تاریخ انتشار 2006