Physical capability outcomes after total disc replacement with ProDisc-L
نویسندگان
چکیده
BACKGROUND Lumbar disc arthroplasty (total disc replacement [TDR]) outcomes have been evaluated using subjective, patient-reported measures of pain, health, and functional impairment. As a condition of TDR coverage, our institution's health plan required that objective physical performance data be collected. Thus our study was designed to explore (1) the feasibility of using preoperative and 1-year postoperative performance on functional capacity tasks as an outcome metric for TDR with ProDisc-L (PD-L) (Synthes Spine, West Chester, Pennsylvania), (2) the magnitude and significance of changes in preoperative and postoperative performance, and (3) whether changes noted in performance are reflected in the subjective measures. METHODS Seven adapted WorkWell tasks (physical capability assessment tool [PCAT]) (WorkWell Systems, Duluth, Minnesota) were performed preoperatively and 1 year postoperatively by 18 patients who received either single-level or 2-level PD-L implants. Demographic and medical data were reviewed. RESULTS The PCAT was implemented easily, and the tasks took approximately 30 minutes to complete. Percent improvement and preoperative and postoperative physical capability outcomes for each PCAT task are as follows: squat, 79% (10.7 ± 7.1 repetitions vs 19.2 ± 2.0 repetitions, P < .001); forward bend, 121% (110.2 ± 68.8 seconds vs 243.6 ± 77.2 seconds, P < .001); kneel, 92% (283.2 ± 173.2 seconds vs 544.7 ± 109.3 seconds, P < .001); floor-to-waist lift, 128% (16.1 ± 9.9 lb vs 36.7 ± 20.3 lb, P < .001); horizontal carry, 119% (19.7 ± 8.6 lb vs 43.2 ± 18.3 lb, P < .001); push, 32% (67.7 ± 19.2 lb vs 89.4 ± 24.4 lb, P < .001); and pull, 40% (57.6 ± 17.1 lb vs 80.9 ± 26.4 lb, P < .001). Visual analog scale scores for pain (5.1 ± 1.7 vs 1.4 ± 1.6, P < .001), Oswestry Disability Index scores (49.0% ± 13.2% vs 15.2% ± 14.3%, P < .001), and amount of narcotic use (26.1 ± 43.8 mg of morphine equivalent vs 1.9 ± 7.3 mg of morphine equivalent, P = .031) also improved. In single-level cases, comparison of L4-5 versus L5-S1 showed significant differences only with the forward bend task (P = .002). CONCLUSIONS/CLINICAL RELEVANCE The physical capability outcome may be a feasible outcome metric. PD-L implantation may result in substantial improvements in physical performance. Similar benefits shown in a larger series over a longer timeframe could have important implications for the long-term health, productivity, and cost of health care for this patient population.
منابع مشابه
Two- to 3-Year Follow-Up of ProDisc-L: Results From a Prospective Randomized Trial of Arthroplasty Versus Fusion
BACKGROUND Although total disc replacement has been performed for years outside the United States, relatively little available data address clinical outcomes, particularly data from prospective studies. We report the 24- to 36-month follow-up of one center's experience with the ProDisc-L artificial disc as part of a prospective, randomized trial comparing total disc arthroplasty to combined ant...
متن کاملThe Correlation between Insertion Depth of Prodisc-C Artificial Disc and Postoperative Kyphotic Deformity: Clinical Importance of Insertion Depth of Artificial Disc
OBJECTIVE This study was designed to investigate the correlation between insertion depth of artificial disc and postoperative kyphotic deformity after Prodisc-C total disc replacement surgery, and the range of artificial disc insertion depth which is effective in preventing postoperative whole cervical or segmental kyphotic deformity. METHODS A retrospective radiological analysis was performe...
متن کاملClinical study to evaluate the safety and effectiveness of the Aesculap Activ-L™ artificial disc in the treatment of degenerative disc disease
BACKGROUND The objective of this clinical study is to evaluate the safety and effectiveness of the Activ-L Artificial Disc for treatment of single-level degenerative disc disease of the lumbar spine in patients who have been unresponsive to at least six months of prior conservative care. The hypothesis of the study is that the Activ-L Disc is non-inferior to the control (the Charité Artificial ...
متن کاملCervical arthroplasty using ProDisc-C Case Report
Cervical disc replacement is an emerging motion-preserving technology in the surgical treatment of the cervical degenerative disc disorders used as an alternative to the classic interbody fusion. We present a case report of a patient diagnosed with C6-7 right disc herniation who underwent anterior discectomy and received a total disc replacement using ProDisc C artificial disc prosthesis.
متن کاملTwelve-Month Follow-up of Lumbar Spine Range of Motion Following Intervertebral Disc Replacement Using Radiostereometric Analysis
BACKGROUND Many clinical studies have focused on clinical pain scores and less on kinematics following intervertebral disc replacement. Although flexion and extension of the motion segment can be measured on lateral X-rays, measuring lateral bending and axial rotation of the device is extremely difficult on plain radiography. This study was designed to measure, using radiostereometric analysis ...
متن کامل