MR angiography of aneurysm models of various shapes and neck sizes.

نویسندگان

  • H Isoda
  • R G Ramsey
  • Y Takehara
  • M Takahashi
  • M Kaneko
چکیده

PURPOSE To investigate the signal intensity of lateral and terminal saccular aneurysm models with differing neck sizes using three-dimensional time-of-flight (TOF) MR angiography with various imaging parameters. METHODS The study included four lateral and four terminal saccular aneurysm models with pulsatile flow. The height and fundus diameter were 10 mm; the neck diameters were 2.5 mm, 5 mm, 7.5 mm, and 10 mm, respectively. Each aneurysm model was examined with fast imaging with steady-state precession MR sequences with parameters of 20-140/7 (repetition time/echo time) and flip angles of 10 degrees to 30 degrees. Signal intensity was measured and compared among the models. RESULTS Three-dimensional TOF MR angiography with the shorter repetition time and/or larger flip angle showed weaker signal intensity in the aneurysm models. Stronger signal intensity was obtained in the terminal saccular aneurysm models and/or the models with a wider neck than in the lateral saccular aneurysm models and/or the models with a narrower neck. In some aneurysm models, longer repetition times produced greater signal intensity than that of background brain models, but not in aneurysms with narrow necks. CONCLUSION Noncontrast 3-D TOF MR angiography delineated terminal saccular aneurysms and/or aneurysms with wider necks and did not delineate lateral saccular aneurysms and/or aneurysms with narrower necks. Longer repetition times are recommended to allow the spins flowing into the aneurysms to recover.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tagged MR imaging of intracranial aneurysm models.

We used tagged MR imaging to investigate the flow in two lateral and two terminal saccular intracranial aneurysm models of different neck sizes. Imaging was performed with a 1.5-T superconducting MR system using 2D fast spatial modulation of magnetization (SPAMM) sequences with an intersegmental delay of 25 milliseconds. The flow in the saccular aneurysm models varied with the shape and size of...

متن کامل

Intracranial aneurysms treated with Guglielmi detachable coils: usefulness of 6-month imaging follow-up with contrast-enhanced MR angiography.

BACKGROUND AND PURPOSE This study was undertaken to assess the utility of contrast-enhanced MR angiography at 6 months after endovascular treatment of intracranial aneurysms with Guglielmi detachable coils. METHODS Contrast-enhanced MR angiography was performed in 47 patients at 6 and 12 months after endovascular treatment of intracranial aneurysms (48 aneurysms). Digital subtraction angiogra...

متن کامل

In vitro evaluation of 2D-digital subtraction angiography versus 3D-time-of-flight in assessment of intracranial cerebral aneurysm filling after endovascular therapy.

BACKGROUND AND PURPOSE The aim of this study was to evaluate 2D-digital subtraction angiographic (DSA) and 3D-time-of-flight (TOF) MR imaging in assessment of aneurysmal residue by using a pulsating silicon aneurysm model. For each imaging system, we studied intra- and interobserver reproducibility and the agreement between interpretations and reference measurements. We also examined how each i...

متن کامل

Intravascular virtual MR endoscopy evaluation of cerebral aneurysms.

AIM The aim of this study was to evaluate the role of intravascular virtual MR endoscopy in the planning of correct surgical clipping of the aneurysm neck. MATERIAL AND METHODS A total of 36 aneurysms were detected by using magnetic resonance angiography (MRA) in thirty patients. Intravascular virtual MR endoscopy is a realistic 3-dimensional simulation of intravascular structures that is gen...

متن کامل

Intracranial aneurysms treated with Guglielmi detachable coils: imaging follow-up with contrast-enhanced MR angiography.

BACKGROUND AND PURPOSE To compare the utility of contrast-enhanced MR Angiography (CE-MRA) with digital subtraction angiography (DSA) after endovascular treatment of intracranial aneurysms with Guglielmi detachable coils. METHODS From April 1999 to August 2002, 106 patients with 107 aneurysms treated by endovascular coiling using Guglielmi detachable coils underwent simultaneous DSA and CE-MR...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 18 8  شماره 

صفحات  -

تاریخ انتشار 1997