Heat transfer in nucleate pool boiling of multicomponent mixtures
نویسندگان
چکیده
Steady state pool boiling heat transfer coefficients have been obtained experimentally for acetone–isopropanol–water and acetone–MEK (methyl ethyl ketone)–water ternary systems. The data show that, for a given heat flux, the heat transfer coefficients of mixtures are lower than those obtained for pure components constituting the mixture. The measured heat transfer coefficients were compared with predictions from literature correlations for pool boiling of multicomponent mixtures. In all the cases, overestimation or underestimation of the data was observed. The literature correlations incorporate an ‘ideal’ heat transfer coefficient and a correction term for the presence of other liquids. Part of the uncertainty associated with the literature correlations on comparison with the present data appears to be due to the uncertainty in estimating the ideal heat transfer coefficient. The methods suggested by the earlier authors found to be not applicable for the present heating surface–liquid combinations. Therefore, in the present study, two different correlations were tried for the ideal heat transfer coefficient and it was found that the performance of the literature correlations improved considerably. However, the methods reported in the literature and the correlations tried in the present study to estimate ideal heat transfer coefficient did not consider heating surface–liquid interaction and the effect of heating surface microroughness in boiling. Therefore, a correlation to estimate the ideal heat transfer coefficient has been proposed taking into account surface–liquid interaction parameter and surface roughness group. A new correlation to estimate mixture heat transfer coefficients has been proposed in the present study in terms of an ideal heat transfer coefficient and a correction term. In general, the correction term in binary mixtures is obtained by incorporating the binary diffusivity of the mixture. In multicomponent systems, the multicomponent diffusion coefficients have to be incorporated in the expression for the correction term. The mixture heat transfer coefficient correlation along with the correlation for ideal heat transfer coefficient proposed in the present study predicts the present experimental data as well as literature data satisfactorily. The heat transfer coefficient was found to be a function of the difference between the equilibrium vapor and liquid concentration of the light component(s) and the minimum heat transfer coefficient occurs at the maximum of this value. 2004 Elsevier Inc. All rights reserved.
منابع مشابه
Experimental Investigation in Pool Boiling Heat Transfer of Pure/Binary Mixtures and Heat Transfer Correlations
Nucleate pool boiling heat transfer coefficient have been experimentally measured on a horizontal rod heater for various liquid binary mixtures. Measurements are based on more than three hundred data points on a wide range of concentrations and heat fluxes. In this investigation, it has been confirmed that the heat transfer coefficient in boiling solutions are regularly less than those in p...
متن کاملPool Boiling Heat Transfer in Water/Amines Solutions
In this investigation, nucleate boiling heat transfer coefficients were experimentally measured during pool boiling of mixtures, consisting of water/monoethanolamine and water/diethanolamine on a horizontal heating rod, under atmospheric pressure. The experiment was carried out below 205 kW.m-2 heat flux, over a wide range of concentrations. These experiments include, measurement of pool boilin...
متن کاملExperimental Study for Investigating the Mechanism of Heat Transfer near the Critical Heat Flux in Nucleate Pool Boiling
Heat transfer coefficient in nucleate pool boiling near critical heat flux at least one orderhigher than the convectional heat transfer modes. In this paper, an experimental setup isdesigned and fabricated to investigate the mechanism of heat transfer from boiling surface tobulk liquid near critical heat flux. The images of pool boiling near the high heat flux regionreveals that the individual ...
متن کاملMechanism and Prevention of Scale Formation in Boilers
Nucleate boiling heat transfer coefficients may be strongly reduced by scale formation, even for conditions where the bulk foulant concentration is well below the saturation concentration. Due to the mechanism of micro-layer evaporation, the local concentration at the heat transfer surface can be considerably increased, causing the formation of scale and changes in bubble frequency and bubble d...
متن کاملTwo Phase Heat Transfer Characteristics in a Vertical Small Diameter Tube at Sub Atmospheric Pressure
Two-phase heat transfer is experimentally examined through vertical small diameter tubes, D =1.45 and 2.8 mm using water under a pressure of 50 to 81 kPa and a natural circulation condition. The pool boiling correlation by Stephan-Abdelsalam and the thermosyphon boiling correlation by Imura, et al. predict the measured experimental data in the 2.8 mm tube with an error of -30%. A large heat tra...
متن کامل