Percutaneous valve-in-valve transcatheter tricuspid valve replacement with simultaneous paravalvular leak closure in a patient with refractory right heart failure.
نویسندگان
چکیده
A 38-year-old male patient presented to our hospital with a 3-month history of shortness of breath in combination with severe peripheral edema and ascites. Twenty-two years previously, he had undergone bioprosthetic tricuspid valve implantation due to Ebstein anomaly. Transthoracic echocardiography revealed significantly dilated right cardiac chambers, reduced right ventricular function, stenotic and degenerated bioprosthetic tricuspid valve, and marked tricuspid insufficiency associated with a 22-mm paravalvular defect located lateral to the valve (Fig. 1, Online Videos 1, 2, and 3). Cardiac computed tomography also revealed significantly dilated right cardiac chambers and a 24-mm defect located lateral to the valve.
منابع مشابه
Transcatheter Aortic Valve Replacement: A Review Article
Transcatheter aortic valve replacement (TAVR) is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive p...
متن کاملTranscatheter Closures for Fistula Tract and Paravalvular Leak after Mitral Valve Replacement and Tricuspid Annuloplasty
Paravalvular leaks (PVLs) often occur after surgical valve replacement. Surgical reoperation has been the gold standard of therapy for PVLs, but it carries a higher operative risk and an increased incidence of re-leaks compared to the initial surgery. In high surgical risk patients with appropriate geometries, transcatheter closure of PVLs could be an alternative to redo-surgery. Here, we repor...
متن کاملRight sided heart evaluation after successful mitral valve replacement.
Introduction: It is well-documented that right-sided heart dysfunction and significant tricuspid valve regurgitation (TVR) have adverse effects on patient outcomes after left-sided heart valve surgery. Therefore, the evaluation of right ventriclular (RV) function and TR severity in patients who had undergone mitral valve replacement (MVR), associated with/without concomitant su...
متن کاملPercutaneous closure of paravalvular leak after transcatheter aortic valve replacement.
An 86-year-old male underwent TAVR with a 26 mm Sapien valve, co valve, moderate-to-severe paravalvular AI persisted. The patient quick catheter was advanced across the tract over a stiff angled glidewire; a reduction of AI and rapid clinical recovery. (A) TEE long-axis and (B) shor confirms the 4-F MP catheter has been advanced outside the struts of th resulting in substantial reduction of AI ...
متن کاملPercutaneous Closure of an Aortic Prosthetic Paravalvular Leak with Device in a Patient Presenting with Heart Failure
Paravalvular leaks (PVLs) are a well-recognized complication of prosthetic valve replacement. Perivalvular prosthetic regurgitation causes significant morbidity and is associated with high perioperative mortality if open surgical repair is required. PVLs manifest with symptoms of congestive heart failure, hemolysis, or in most cases, the combination of both. In recent years, the development of ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- JACC. Cardiovascular interventions
دوره 7 7 شماره
صفحات -
تاریخ انتشار 2014