Balloon atrial septostomy via the umbilical vein.
نویسندگان
چکیده
منابع مشابه
Balloon atrial septostomy under echocardiographic control: six years' experience and evaluation of the practicability of cannulation via the umbilical vein.
Balloon atrial septostomy was undertaken under cross sectional echocardiographic control in 63 consecutive infants: in no case was fluoroscopic imaging required. The procedure was performed in the cardiac catheterisation laboratory, ward side room, or at the bedside in the neonatal intensive care unit. Catheterisation via the umbilical vein was attempted in 37 infants aged less than 48 hours ol...
متن کاملسپتوستومی دهلیزی با راهنمایی اکوکاردیوگرافی: گزارش هشت بیمار
Background: Balloon atrial septostomy is an emergent procedure in pediatric cardiology. Nowadays, most patients in need of the procedure have acceptable outcomes after surgical repair. Thus, it is important to perform this procedure as safe as possible. By performing early arterial switch operation and prostaglandin infusion, the rate of balloon atrial septostomy has markedly decreased. Howeve...
متن کامل[Echocardiographic monitoring of balloon atrial septostomy].
OBJECTIVE To assess balloon atrial septostomy monitored with echocardiography. METHODS From August 1997 to January 2004, 31 infants with congenital heart diseases indicated for balloon atrial septostomy underwent the procedure with exclusive echocardiographic monitoring. Success was defined as the obtainment of an atrial septal defect diameter > 4 mm and ample mobility of its margins. RESUL...
متن کاملBalloon atrial septostomy under two dimensional echocardiographic control.
Two dimensional echocardiography has been used to guide balloon atrial septostomy in five cases of transposition of the great arteries. A single lumen balloon catheter was used. The catheter can be accurately located within the left atrium before inflation of the balloon, thus avoiding some of the traumatic accidents possible during septostomy. The balloon can be observed creating the atrial de...
متن کاملBalloon embolization during atrial septostomy.
SUMMARY The case of an infant with complete transposition is presented. Embolization occurred from a balloon catheter used in performing a Rashkind septostomy. Additional Indexing Words: Oxygenation Renal infarction T HE USE of atrial septostomy as a temporary means of improving systemic oxygenation in infants with transposition of the great vessels was introduced by Rashkind and Miller in 1966...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British heart journal
دوره 36 10 شماره
صفحات -
تاریخ انتشار 1974