Vasopressor response in a porcine model of hypothermic cardiac arrest is improved with active compression-decompression cardiopulmonary resuscitation using the inspiratory impedance threshold valve.
نویسندگان
چکیده
UNLABELLED During normothermic cardiac arrest, a combination of active compression-decompression (ACD) cardiopulmonary resuscitation (CPR) with the inspiratory threshold valve (ITV) significantly improves vital organ blood flow, but this technique has not been studied during hypothermic cardiac arrest. Accordingly, we evaluated the hemodynamic effects of ACD + ITV CPR before, and after, the administration of vasopressin in a porcine model of hypothermic cardiac arrest. Pigs were surface-cooled until their body core temperature was 26 degrees C. After 10 min of untreated ventricular fibrillation, 14 animals were randomly assigned to either ACD CPR with the ITV (n = 7) or to standard (STD) CPR (n = 7). After 8 min of CPR, all animals received 0.4 U/kg vasopressin IV, and CPR was maintained for an additional 10 min in each group; defibrillation was attempted after 28 min of cardiac arrest, including 18 min of CPR. Before the administration of vasopressin, mean +/- SEM common carotid blood flow was significantly higher in the ACD + ITV group compared with STD CPR (67 +/- 13 versus 26 +/- 5 mL/min, respectively; P < 0.025). After vasopressin was given at minute 8 during CPR, mean +/- SEM coronary perfusion pressure was significantly higher in the ACD + ITV group, but did not increase in the STD group (29 +/- 3 versus 15 +/- 2 mm Hg, and 25 +/- 1 versus 14 +/- 1 mm Hg at minute 12 and 18, respectively; P < 0.001); mean +/- SEM common carotid blood flow remained higher at respective time points (33 +/- 8 versus 10 +/- 3 mL/min, and 31 +/- 7 versus 7 +/- 3 mL/min, respectively; P < 0.01). Without active rewarming, spontaneous circulation was restored and maintained for 1 h in three of seven animals in the ACD + ITV group versus none of seven animals in the STD CPR group (not significant). During hypothermic cardiac arrest, ACD CPR with the ITV improved common carotid blood flow compared with STD CPR alone. Moreover, after the administration of vasopressin, coronary perfusion pressure was significantly higher during ACD + ITV CPR, but not during STD CPR. IMPLICATIONS New strategies are needed to improve the efficiency of cardiopulmonary resuscitation (CPR) in hypothermic cardiac arrest. Active compression-decompression CPR with the inspiratory threshold valve improved carotid blood flow (and coronary perfusion pressure with vasopressin) compared with standard CPR.
منابع مشابه
Evaluation of an impedance threshold device in patients receiving active compression-decompression cardiopulmonary resuscitation for out of hospital cardiac arrest.
AIMS The purpose of this multicentre clinical randomized controlled blinded prospective trial was to determine whether an inspiratory impedance threshold device (ITD), when used in combination with active compression-decompression (ACD) cardiopulmonary resuscitation (CPR), would improve survival rates in patients with out-of-hospital cardiac arrest. METHODS AND RESULTS Patients were randomize...
متن کاملUse of an inspiratory impedance threshold valve during cardiopulmonary resuscitation: a progress report.
Building upon studies on the mechanism of active compression-decompression (ACD) cardiopulmonary resuscitation, a new inspiratory impedance threshold valve has been developed to enhance the return of blood to the thorax during the decompression phase of CPR. Use of this device results in a greater negative intrathoracic pressure during chest wall decompression. This leads to improved vital orga...
متن کاملUtilization of a model lung system to assess the effects of an inspiratory impedance threshold valve on the relationship between active decompression and intra-thoracic pressure.
Use of an inspiratory impedance valve has recently been shown to increase the efficacy of standard and active compression-decompression cardiopulmonary resuscitation. We evaluated the effects of a prototypic impedance valve on the relationship between the active decompression and intra-thoracic pressure using a mechanical model lung system. Intermittent impedance to inspiratory flow of respirat...
متن کاملEvaluation of a prototypic inspiratory impedance threshold valve designed to enhance the efficiency of cardiopulmonary resuscitation.
OBJECTIVE Assess a prototype inspiratory impedance threshold valve (ITV) designed to enhance vital organ circulation during standard and active compression/decompression cardiopulmonary resuscitation (CPR). BACKGROUND The ITV attaches to commonly used airway assist devices and decreases intrathoracic pressure during the decompression (chest recoil) phase of CPR by creating a vacuum within the...
متن کاملThe effects of positive end-expiratory pressure during active compression decompression cardiopulmonary resuscitation with the inspiratory threshold valve.
UNLABELLED The use of an inspiratory impedance threshold valve (ITV) during active compression-decompression (ACD) cardiopulmonary resuscitation (CPR) improves perfusion pressures, and vital organ blood flow. We evaluated the effects of positive end-expiratory pressure (PEEP) on gas exchange, and coronary perfusion pressure gradients during ACD + ITV CPR in a porcine cardiac arrest model. All a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Anesthesia and analgesia
دوره 95 6 شماره
صفحات -
تاریخ انتشار 2002