Development of a traceable calibration methodology for solid (68)Ge/(68)Ga sources used as a calibration surrogate for (18)F in radionuclide activity calibrators.
نویسندگان
چکیده
UNLABELLED We have developed a methodology for calibrating (68)Ge radioactivity content in a commercially available calibration source for activity calibrators in a way that is traceable to the national standard. Additionally, the source was cross-calibrated for equivalent (18)F content by direct comparison with the national standard for (18)F in the same geometry. METHODS Sources containing standardized (68)GeCl(4) or (18)F-FDG solutions were prepared at the National Institute of Standards and Technology (NIST) with mock syringe blanks used in the construction of a commercially available epoxy-based (68)Ge calibration source. These sources and several NIST-constructed epoxy-based (68)Ge mock syringes were then used as artifact standards to determine calibration factors for NIST-maintained activity calibrators and secondary standard ionization chambers to enable calibration of the actual commercial sources. A direct comparison between the solution-based (68)Ge sources and the (18)F-FDG sources allowed for an empiric determination of the relative response for these radionuclides in several commercial activity calibrators. Potential measurement effects due to differences between the solution composition and the epoxy and theoretic (68)Ge-to-(18)F response ratios were studied by Monte Carlo simulation. RESULTS The calibration factors developed in this study enabled NIST to calibrate epoxy-based mock syringe sources with a relative combined standard uncertainty of 0.52%. The direct comparisons of the (68)Ge and (18)F standards in the various ionization chambers allowed the activity to be expressed in terms of equivalent (18)F activity with a relative combined standard uncertainty of about 0.9%. CONCLUSION The ability for NIST to calibrate these epoxy-based mock syringes enabled, for the first time to our knowledge, the direct traceability to the national (68)Ge standard to be established for this type of source. Through a direct comparison with the NIST (18)F standard, the determination of the relative response ratios in activity calibrators enabled the equivalent (18)F activity to be determined in a way that was also traceable to the national (18)F activity standard.
منابع مشابه
Performance assessment of a NaI(Tl) gamma counter for PET applications with methods for improved quantitative accuracy and greater standardization
BACKGROUND Although NaI(Tl) gamma counters play an important role in many quantitative positron emission tomography (PET) protocols, their calibration for positron-emitting samples has not been standardized across imaging sites. In this study, we characterized the operational range of a gamma counter specifically for positron-emitting radionuclides, and we assessed the role of traceable (68)Ge/...
متن کاملStandardization of 68Ge/68Ga Using Three Liquid Scintillation Counting Based Methods
A solution containing (68)Ge in equilibrium with its daughter, (68)Ga, has been standardized for the first time at the National Institute of Standards and Technology (NIST) using 3 liquid scintillation-based techniques: live-timed 4πβ -γ anticoincidence (LTAC) counting, the Triple-to-Double Coincidence Ratio (TDCR) method, and (3)H-standard efficiency tracing with the CIEMAT(1)/NIST (CNET) meth...
متن کاملAn overview on Ga-68 radiopharmaceuticals for positron emission tomography applications
Gallium-68 a positron emitter radionuclide, with great impact on the nuclear medicine, has been widely used in positron emission tomography (PET) diagnosis of various malignancies in humans during more recent years especially in neuroendocrine tumors (NETs). The vast number of 68Ge/68Ga related generator productions, targeting molecule design (proteins, antibody fragments,...
متن کاملCalibration of Traceable Solid Mock 131I Phantoms Used in an International SPECT Image Quantification Comparison
The International Atomic Energy Agency (IAEA) has organized an international comparison to assess Single Photon Emission Computed Tomography (SPECT) image quantification capabilities in 12 countries. Iodine-131 was chosen as the radionuclide for the comparison because of its wide use around the world, but for logistical reasons solid (133)Ba sources were used as a long-lived surrogate for (131)...
متن کاملMaturation of a key resource - the germanium-68/gallium-68 generator: development and new insights.
(68)Ge/(68)Ga radionuclide generators have been investigated for almost fifty years, since the cyclotron-independent availability of positron emitting (68)Ga via the (68)Ge/(68)Ga system had always attracted researches working in basic nuclear chemistry as well as radiopharmaceutical chemistry. However, it took decades and generations of research (and researchers) to finally reach a level of (6...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 51 3 شماره
صفحات -
تاریخ انتشار 2010