A multi-sensor upper tropospheric ozone product (MUTOP) based on TES ozone and GOES water vapor: validation with ozonesondes
نویسندگان
چکیده
Accurate representation of ozone in the extratropical upper troposphere (UT) remains a challenge. However, the implementation of hyper-spectral remote sensing using satellite instruments such as the Tropospheric Emission Spectrometer (TES) provides an avenue for mapping ozone in this region, from 500 to 300 hPa. As a polar orbiting satellite TES observations are limited, but in this paper they are combined with geostationary satellite observations of water vapor. This paper describes a validation of the Multi-sensor UT Ozone Product (MUTOP). MUTOP, based on a statistical retrieval method, is an image product derived from the multiple regression of remotely sensed TES ozone, against geostationary (GOES) specific humidity (remotely sensed) and potential vorticity (a modeled dynamical tracer in the UT). These TES-derived UT ozone mixing ratios are compared to coincident ozonesonde measurements of layer-average UT ozone mixing ratios made during the NASA INTEX/B field campaign in the spring of 2006; the region for this study is effectively the GOES west domain covering the eastern North Pacific Ocean and the western United States. This intercomparison evaluates MUTOP skill at representing ozone magnitude and variability in this region of complex dynamics. In total, 11 ozonesonde launch sites were available for this study, providing 127 individual sondes for comparison; the overall mean ozone of the 500–300 hPa layer for these sondes was 78.0 ppbv. MUTOP reproduces in situ measurements reasonably well, producing an UT mean of 82.3 ppbv, with a mean absolute error of 12.2 ppbv and a root mean square error of 16.4 ppbv relative to ozonesondes across all sites. An overall UT mean bias of 4.3 ppbv relative to sondes was determined for MUTOP. Considered in the context of past TES validation studies, these results illustrate that MUTOP is able to maintain accuracy similar to TES while expanding coverage to the entire GOES-West satellite domain. In addition MUTOP provides six-hour temporal resolution throughout the INTEX-B study period, making the visualization of UT ozone dynamics possible. This paper presents the overall statistical validation as well as a selection of ozonesonde case studies. The case studies illustrate that error may not always represent a lack of TES-derived product skill, but often results from discrepancies driven by observations made in the presence of strong meteorological gradients.
منابع مشابه
A multi-sensor upper tropospheric ozone product (MUTOP) based on TES Ozone and GOES water vapor: derivation
The Tropospheric Emission Spectrometer (TES), a hyperspectral infrared instrument on the Aura satellite, retrieves a vertical profile of tropospheric ozone. However, polar-orbiting instruments like TES provide limited nadirview coverage. This work illustrates the value of these observations when taken in context with geostationary imagery describing synoptic-scale weather patterns. The goal of ...
متن کاملValidation of Tropospheric Emission Spectrometer (TES) measurements of the total, stratospheric, and tropospheric column abundance of ozone
[1] The Tropospheric Emission Spectrometer (TES) is an infrared, high-resolution Fourier transform spectrometer which was launched onboard NASA’s Aura satellite in 2004 and is providing global, vertically resolved measurements of ozone in the troposphere. TES version 2 (V002) data profiles have been validated in the troposphere and lower stratosphere by way of comparison to ozonesondes and airc...
متن کاملValidation of six years of TES tropospheric ozone retrievals with ozonesonde measurements: implications for spatial patterns a d temporal stability in the bias
In this analysis, Tropospheric Emission Spectrometer (TES) V004 nadir ozone (O3) profiles are validated with more than 4400 coinciding ozonesonde measurements taken across the world from the World Ozone and Ultraviolet Radiation Data Centre (WOUDC) during the period 2005–2010. The TES observation operator was applied to the sonde data to ensure a consistent comparison between TES and ozonesonde...
متن کاملImpact of surface emissions to the zonal variability of tropical tropospheric ozone and carbon monoxide for November 2004
The chemical and dynamical processes governing the zonal variability of tropical tropospheric ozone and carbon monoxide are investigated for November 2004 using satellite observations, in-situ measurements, and chemical transport models in conjunction with inverse estimated surface emissions. Vertical ozone profile estimates from the Tropospheric Emission Spectrometer (TES) and ozone sonde meas...
متن کاملStudy of tropospheric ozone concentration trend of Kermanshah by meteorological parameter and ozone precursor and OMI images
Abstract: Clean air is a necessity for human well-being and health. Air pollution is a major threat to humans and other organisms and is considered as one of the environmental challenges. Today, with the increase in air pollution, the need to know more about the causes of its occurrence has been raised. The various consequences of air pollution have made air quality monitoring and control inev...
متن کامل