Quality specifications for glucose meters: assessment by simulation modeling of errors in insulin dose.

نویسندگان

  • J C Boyd
  • D E Bruns
چکیده

BACKGROUND Proposed quality specifications for glucose meters allow results to be in error by 5-10% or more of the "true" concentration. Because meters are used as aids in the adjustment of insulin doses, we aimed to characterize the quantitative effect of meter error on the ability to identify the insulin dose appropriate for the true glucose concentration. METHODS Using Monte Carlo simulation, we generated random "true" glucose values within defined intervals. These values were converted to "measured" glucose values using mathematical models of glucose meters having defined imprecision (CV) and bias. For each combination of bias and imprecision, 10,000-20,000 true and measured glucose concentrations were matched with the corresponding insulin doses specified by selected insulin-dosing regimens. Discrepancies in prescribed doses were counted and their frequencies plotted in relation to bias and imprecision. RESULTS For meters with a total analytical error of 5%, dosage errors occurred in approximately 8-23% of insulin doses. At 10% total error, 16-45% of doses were in error. Large errors of insulin dose (two-step or greater) occurred >5% of the time when the CV and/or bias exceeded 10-15%. Total dosage error rates were affected only slightly by choices of sliding scale among insulin dosage rules or by the range of blood glucose. To provide the intended insulin dosage 95% of the time required that both the bias and the CV of the glucose meter be <1% or <2%, depending on mean glucose concentrations and the rules for insulin dosing. CONCLUSIONS Glucose meters that meet current quality specifications allow a large fraction of administered insulin doses to differ from the intended doses. The effects of such dosage errors on blood glucose and on patient outcomes require study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Predicted blood glucose from insulin administration based on values from miscoded glucose meters.

OBJECTIVES The proper use of many types of self-monitored blood glucose (SMBG) meters requires calibration to match strip code. Studies have demonstrated the occurrence and impact on insulin dose of coding errors with SMBG meters. This paper reflects additional analyses performed with data from Raine et al. (JDST, 2:205-210, 2007). It attempts to relate potential insulin dose errors to possible...

متن کامل

Effects of measurement frequency on analytical quality required for glucose measurements in intensive care units: assessments by simulation models.

BACKGROUND Total error allowances have been proposed for glucose meters used in tight-glucose-control (TGC) protocols. It is unclear whether these proposed quality specifications are appropriate for continuous glucose monitoring (CGM). METHODS We performed Monte Carlo simulations of patients on TGC protocols. To simulate use of glucose meters, measurements were made hourly. To simulate CGM, g...

متن کامل

Glucose meter performance criteria for tight glycemic control estimated by simulation modeling.

BACKGROUND Glucose meter analytical performance criteria required for safe and effective management of patients on tight glycemic control (TGC) are not currently defined. We used simulation modeling to relate glucose meter performance characteristics to insulin dosing errors during TGC. METHODS We used 29,920 glucose values from patients on TGC at 1 institution to represent the expected distr...

متن کامل

Importance of blood glucose meter and carbohydrate estimation accuracy.

BACKGROUND The clinical significance of blood glucose meter (BGM) error in the presence of increasing carbohydrate errors in diabetes patients who use both the BGM result and the carbohydrate estimation to dose insulin is unknown. METHODS This Monte Carlo simulation modeled diabetes patients who calculate insulin dosages based on BGM results and carbohydrate estimations. It evaluated the like...

متن کامل

Intelligent blood glucose control in diabetic patients: design and simulation of an artificial pancreas

Background: Diabetes mellitus (DM) is a common chronic disease with diverse complications. About 10% of the earth's population suffer from this disease. For smart control of the blood glucose in DM patients, an artificial pancreas was designed and simulated by a predictive sliding mode controller considering the time delay of insulin effect. Method: In this method, one of the time-delay glucos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 47 2  شماره 

صفحات  -

تاریخ انتشار 2001