Computation of equilibria in models of flue gas washer plants

نویسندگان

  • Wolfgang Desch
  • Karin Horn
  • Georg Propst
چکیده

7 A flue gas washer is a plant for the absorption of noxious components of industrial gas output. The type of flue gas washers that is considered here is a spray tower. In the tower gas is raising upward and water drops with suspended limestone fall downward. Thereby sulfur dioxide is washed out of the gas. In industrial practice, the plant is operated under long term constant gas and water input. In this article, a mathematical model for equilibrium states of the plant is set up from basic principles. Its discretized version consists of a large system of algebraic equations for the relevant chemical concentrations in the two phases. An efficient iterative algorithm for solving this system is proposed and shown to converge in a wide range of examples. A satisfactory validation of the model is given by comparison with experimental data from existing literature. It is demonstrated that the model along with the algorithm is applicable for the design of spray towers. 8

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Fugacity Approach for Prediction of Phase Equilibria of Methane Clathrate Hydrate in Structure H

In this communication, a thermodynamic model is presented to predict the dissociation conditions of structure H (sH) clathrate hydrates with methane as help gas. This approach is an extension of the Klauda and Sandler fugacity model (2000) for prediction of phase boundaries of sI and sII clathrate hydrates. The phase behavior of the water and hydrocarbon system is modeled using the Peng-Robinso...

متن کامل

A Numerical Study on Using Air Cooler Heat Exchanger for Low Grade Energy Recovery from Exhaust Flue Gas in Natural Gas Pressure Reduction Stations

Heat EXchangers (HEX) that are used in City Gate Station (CGS) systems are modeled numerically to recover the exhaust waste heat. It was tried to find the best viscous model to obtain results in accordance with experimental results and to change the heat exchanger design. This HEX is used for recovering heat from exhaust flue gas with a mixture of 40% water and 60% ethylene glycol as the coolin...

متن کامل

Effect of Sealing Gas Washer Design on a PEM Stack Fuel Cell Performance

In this paper we study the performance of a PEM stack fuel cell after 900 hours of operation. We tried to identify any voltage degradation and its causes. Microscopic cracks on some parts of MEA mainly due to uniformity of pressure, stress concentration and elongation of membrane in the edge of GDL has been identified as the most important cause of this gradual degradation. High contact resista...

متن کامل

Modeling of CO2 Removal from Gas Mixtureby 2-amino-2-methyl-1-propanol (AMP) Using the Modified Kent Eisenberg Model

In this paper, the solubility of CO2 in AMP solution have been measured at temperature range of ( 293, 303 ,313,323) K.The amine concentration ranges studied are (2.0, 2.8, and 3.4) M. A solubility apparatus was used to measure the solubility of CO2 in AMP solution on samples of flue gases from Thermal and Central Power Plants of Esfahan Steel Company. The modified Kent Eisenberg model was used...

متن کامل

Experimental Investigation and Modeling of Carbon Dioxide Adsorption from Model Flue gas

In this work, the adsorption of carbon dioxide from model flue gas on different adsorbents has been investigated. Using simplified modeling, parameters such as the total mass transfer coefficient and the effective diffusivity have been determined. Experiments were carried out in two sections: firstly, adsorption of pure carbon dioxide on different adsorbents was measured at pressures ranging fr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Computers & Chemical Engineering

دوره 30  شماره 

صفحات  -

تاریخ انتشار 2006