Efficient monitoring of the blood-stage infection in a malaria rodent model by the rotating-crystal magneto-optical method

نویسندگان

  • Ágnes Orbán
  • Maria Rebelo
  • Petra Molnár
  • Inês S. Albuquerque
  • Adam Butykai
  • István Kézsmárki
چکیده

Intense research efforts have been focused on the improvement of the efficiency and sensitivity of malaria diagnostics, especially in resource-limited settings for the detection of asymptomatic infections. Our recently developed magneto-optical (MO) method allows the accurate quantification of malaria pigment crystals (hemozoin) in blood by their magnetically induced rotation. First evaluations of the method using β-hematin crystals and in vitro P. falciparum cultures implied its potential for high-sensitivity malaria diagnosis. To further investigate this potential, here we study the performance of the method in monitoring the in vivo onset and progression of the blood-stage infection in a rodent malaria model. Our results show that the MO method can detect the first generation of intraerythrocytic P. berghei parasites 66-76 hours after sporozoite injection, demonstrating similar sensitivity to Giesma-stained light microscopy and exceeding that of flow cytometric techniques. Magneto-optical measurements performed during and after the treatment of P. berghei infections revealed that both the follow up under treatment and the detection of later reinfections are feasible with this new technique. The present study demonstrates that the MO method - besides being label and reagent-free, automated and rapid - has a high in vivo sensitivity and is ready for in-field evaluation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Efficient monitoring of blood-stage infection in a malaria rodent model by the rotating-crystal magneto-optical method

Intense research efforts have been focused on the improvement of the efficiency and sensitivity of malaria diagnostics, especially in resource-limited settings for the detection of asymptomatic infections. A recently developed magneto-optical (MO) method allows for the high-sensitivity detection of malaria pigment (hemozoin) crystals in blood via their magnetically induced rotational motion. Fi...

متن کامل

The Effects of Splenectomy on Pattern of Nitric Oxide Induction and Pathogenesis of Rodent Malaria Caused by Plasmodium berghei Infection

Background and Aims: The aim of this study is to clarify nitric oxide (NO)-production by spleen and the importance of spleen in malaria infection in murine model. Materials and Methods: Thirty outbred NMRI female mice were divided into four groups, Group I: No intervention (Healthy control), Group II: With splenectomy (Healthy test), Group III: No intervention, Inoculation of contaminated bloo...

متن کامل

Potent in vivo anti-malaria activity of Goniothalamin against rodent malaria parasite infection in mice

Goniothalamin was evaluated for its anti-malaria activity in-vivo, using the 4-Day Suppressive Test (Peters & Robinson, 1975). The test were carried out against two strains of rodent malaria parasites, the sensitive strain P. berghei ANKA (MRA 311) strain and the resistant strain P. yoelii (MRA 312). An Initial screening was carried out using a single dose of 10 mg/kg body weight administered s...

متن کامل

Potent in vivo anti-malaria activity of Goniothalamin against rodent malaria parasite infection in mice

Goniothalamin was evaluated for its anti-malaria activity in-vivo, using the 4-Day Suppressive Test (Peters & Robinson, 1975). The test were carried out against two strains of rodent malaria parasites, the sensitive strain P. berghei ANKA (MRA 311) strain and the resistant strain P. yoelii (MRA 312). An Initial screening was carried out using a single dose of 10 mg/kg body weight administered s...

متن کامل

Magneto-Optical properties of GaP single crystal

The temperature dependence of magneto-optical and magneto-photoconductivity measurements were carried out in the range of (200-330) K. A home made optical cryostat was used for the measurements. The measured room temperature value of the energy gap was found to be 2.211 eV. The temperature coefficient of energy gap was found to be -5.48×10-4 eV/K obtained by the optical absorption method and -4...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2016