Metallosis and elevated serum levels of tantalum following failed revision hip arthroplasty— a case report

نویسندگان

  • George C Babis
  • Nikolaos A Stavropoulos
  • Gregory Sasalos
  • Maria Ochsenkuehn-Petropoulou
  • Panagiotis Megas
چکیده

1Second Department of Orthopaedics, Konstantopouleio General Hospital N. Ionia, University of Athens Medical School, N. Ionia, Athens; 2First Department of Orthopaedics, “ATTIKON” University General Hospital, University of Athens Medical School, Chaidari, Athens; 3Laboratory of Inorganic and Analytical Chemistry, School of Chemical Engineering, National Technical University of Athens, Athens; 4Department of Orthopaedics, School of Medicine, University of Patras, Patras, Greece. Correspodence: [email protected] Submitted 13-08-17. Accepted 14-03-24

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fatal Cobalt Cardiomyopathy Following Revision Total Hip Arthroplasty – A Brief Report with Review of Literature

Ceramic bearing surfaces are being increasingly used in young patients undergoing total hip arthroplasty. However,failures have been reported including fractures even with the newer third generation ceramics. The recommendedtreatment for fracture of ceramic bearing surfaces is complete synovectomy and revision total hip arthroplasty.However, disappointing results have also bee...

متن کامل

Delamination of tantalum porous coating from a TKA due to regional dissemination of debris.

Metallic debris from metal-on-metal bearings is a recognized mode of failure that may lead to implant loosening and periprosthetic soft tissue reactions. The sequelae of metallosis have been most commonly reported with respect to total hip arthroplasty. The authors report a rare case of metallosis following a hybrid metal-on-polyethylene total knee arthroplasty that used a porous tantalum tibia...

متن کامل

Granulomatous Lung Disease: A Novel Complication following Metallosis from Hip Arthroplasty

A case of a female patient with local and systemic complications of metallosis, following catastrophic wear of a revised hip arthroplasty, is presented. The patient had a history of a fractured ceramic-on-ceramic implant, exchanged with a metal-on-polyethylene prosthesis. Systemic complications included sarcoidosis-like reactions, presenting as granulomatous lung disease, along with chorioretin...

متن کامل

Cobalt toxicity after revision to a metal-on-polyethylene total hip arthroplasty for fracture of ceramic acetabular component

Cobalt metallosis after revision metal-on-polyethylene total hip arthroplasty for catastrophic failure of ceramic components is uncommon but a potentially devastating complication. Common findings associated with heavy metal toxicity include cardiomyopathy, hypothyroidism, skin rashes, visual disturbances, hearing changes, polycythemia, weakness, fatigue, cognitive deterioration, and neuropathy...

متن کامل

Hip Arthroplasty and its Revision in a Child: Case Report and Literature Review

Juvenile idiopathic arthritis is the leading cause of hip replacement in young children. However, arthroplasty in this population is challenging with several concerns about quality of the growing bone, young age for revision surgery, and difficulties in potential several revisions. In this study we introduce a case of a 12-year old who is one of the youngest patients to undergo revision hip art...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 85  شماره 

صفحات  -

تاریخ انتشار 2014