Discerning aortic waves during intra-aortic balloon pumping and their relation to benefits of counterpulsation in humans
نویسندگان
چکیده
An explanation of the mechanisms leading to the beneficial hemodynamic effects of the intra-aortic balloon pump (IABP) is lacking. We hypothesized that inflation and deflation of the balloon would generate a compression (BCW) and an expansion (BEW) wave, respectively, which, when analyzed with wave intensity analysis, could be used to explain the hemodynamic benefits of IABP support. Simultaneous ascending aortic pressure (P(ao)) and flow rate (Q(ao)) were recorded in 25 patients during control conditions and with IABP support of 1:1 and 1:2. Diastolic aortic pressure augmentation (P(aug)) and end-diastolic aortic pressure (ED P(ao)) reduction were calculated from P(ao). Energies of the BCW and BEW were obtained by integrating the wave intensity contour over time. P(aug) was 19.1 mmHg (SD 13.6) during 1:2 support. During 1:1 support significantly higher P(aug) of 21.1 mmHg (SD 13.4) was achieved (P < 0.001). ED P(ao) decreased from 50.9 mmHg (SD 15.1) to 43.9 mmHg (SD 15.7) (P < 0.0001) during 1:1 assistance and the decrease was not statistically different with 1:2. During 1:1 support the energy of BCW was correlated positively to P(aug) (r = 0.83, P < 0.0001) and energy of the BEW correlated negatively to ED P(ao) (r = 0.78, P < 0.005); these relationships were not statistically different during 1:2. In conclusion, the energies of the BCW and BEW are directly related to P(aug) and ED P(ao), which are the conventional hemodynamic parameters indicating IABP benefits. These findings imply a cause and effect mechanism between the energies of BCW and BEW, and IABP hemodynamic effects.
منابع مشابه
Intra-aortic balloon counterpulsation in acute myocardial infarction: too few or too many?
The concept of counterpulsation was introduced over four decades ago by Clauss et al. (1) and adapted to intra-aortic balloon pumping (IABP) by Moulopaulus et al. (2) in 1962, and it remains the most common mode of cardiac assist. Intra-aortic balloon counterpulsation (IABCP) was first introduced into clinical practice by Kantrowitz et al. (3) in 1968 for the treatment of cardiogenic shock. Ini...
متن کاملComplications of Intra - aortic Balloon Insertion and
One hundred consecutive patients considered to be candidates for intra-aortic balloon pumping (IABP) are reviewed from a standpoint of complications and difficulties encountered with balloon catheter insertion. A single attempt at positioning the balloon in the descending thoracic aorta proved successful in 73% of these patients, but the standard femoral artery approach proved difficult in 27% ...
متن کاملTransfemoral transcatheter aortic valve implantation in a patient with a severe aortic stenosis and cardiogenic shock requiring intra-aortic balloon pump support
The following paper presents a patient with severe aortic stenosis and severely reduced left ventricular ejection fraction with intra-aortic balloon pump counterpulsation support, who underwent transfemoral aortic valve implantation of a CoreValve prosthesis.
متن کاملThe Influence of Combined Intra-aortic Balloon Counterpulsation and Hyperosmotic Mannitol on Regional Myocardial Blood Flow in Ischemic Myocardium in the Dog
We investigated the combined effectiveness of intraaortic ballooon counterpulsation and hyperosmotic mannitol (25%) on regional myocardial blood flow during acute coronary insufficiency. Cardiac output and paced heart rate were held constant in chloraloseanesthetized dogs during right heart bypass. Acute coronary insufficiency was produced by ligation of the proximal left anterior descending co...
متن کاملPrevention of Possible Embolus Following Intra Aortic Balloon Counterpulsation (IABP) Insertion by Transesophageal Echocardiography ( TEE )
Severe atherosclerosis of the descending aorta is directly related to atheroembolic events. Transesophageal echocardiography (TEE) is a sensitive technique for evaluating such atheroma plaques of the thoracic aorta which may predict the risk of emboli. We describe a patient with severe intraluminal aortic atherosclerotic plaques detected by TEE while positioning an Intraaortic Balloon Counterpu...
متن کامل