Measurement of antitryptic activity of serum with a centrifugal analyzer.
نویسنده
چکیده
The Selected Method [Clin. Chem. 20, 396 (1974)] for the enzymatic assay of alpha1-antitrypsin in serum has been adapted for use with the E.N.I.-GEMSAEC. With alpha-N-benzoyl-D,L-arginine-p-nitroanilide as substrate, the difference between the tryptic activity measured with and without addition of serum in the same run has been used to calculate the trypsin-inhibitory capacity. The rate of increase in absorbance at 400 nm of the p-nitroanilide formed, has been evaluated during a reaction time of 140 s. Results correlated well (r = 0.986) for 54 human sera analyzed as described here and by the Selected Method. The adaptation on GEMSAEC can be used in detecting alpha1-antitrypsin deficiency in the newborn.
منابع مشابه
Use of a Laser-equipped Centrifugal Analyzer for Kinetic Measurement of Serum lgG
Use of a visible laser in an Aminco “Rotochem” centrifugal analyzer enables light-scattering measurements to be made with this instrument. The modification is technically simple, inexpensive, and requires no fundamental changes in basic instrument design. The laser-modified analyzer has been applied to the measurement of lgG in serum. A two-point kinetic analysis is used to quantitate lgG from ...
متن کاملImmunochemical determination of serum albumin with a centrifugal analyzer.
The turbidity resulting from the reaction between albumin and specific anti-human serum was measured with a good precision by using a GEMSAEC centrifugal analyzer. The reaction was enhanced by polyethylene glycol to shorten the reaction time (5 min) and to displace the point of equivalence between antigen and antibody to an albumin concentration unlikely to occur in human sera (about 100 g/lite...
متن کاملImproved method for measurement of inorganic phosphate in serum with a centrifugal analyzer.
A direct mehtod [Clin. Chim. Acta 46, 113 (1973)] for determination of inorganic phosphate in serum was adapted for use with a centrifugal analyzer. Contamination is minimized and analysis rate maximized by doing the reaction in the reagent wells of the transfer disc and by utilizing the high-speed spectrophotometric and data-reduction capabilities of the centrifugal analyzer. Hemolysis, icteru...
متن کاملSerum alkaline phosphatase: total activity and isoenzyme determinations made by use of the centrifugal fast analyzer.
We present a kinetic method in which the centrifugal analyzer is used to determine total alkaline phosphatase activity and to measure the isoenzymes in bone, liver, and the L-phenylalanine-sensitive fraction (intestine, tumor, and placenta). Measurements were made at 30#{176}C in diethanolamine buffer, with p-nitrophenylphosphate as substrate. The a!kaline phosphatase isoenzymes were separated ...
متن کاملMeasurement of total protein and albumin in serum with a centrifugal analyzer.
In most clinical chemistry laboratories, mechanized procedures are essential for measurement of serum total protein and albumin. The biuret reaction is well established as the most practical approach to mechanized total protein measurements (1-4); albumin has posed a more difficult problem, with several procedures being proposed, some of which have involved salt fractionation (1-4), electrophor...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 23 9 شماره
صفحات -
تاریخ انتشار 1977