Total replacement of the mitral apparatus with a stentless, chordally supported mitral valve allograft: an experimental study.

نویسندگان

  • H Vetter
  • A Nerlich
  • U Welsch
  • K Liao
  • A Dagge
  • C Strenkert
  • B Reichart
چکیده

Mitral valves, including the papillary muscles, were harvested from freshly slaughtered sheep and implanted in 10 recipient growing sheep. A strip of ovine pericardium was used to reinforce the anulus and a patch of expanded polytetrafluoroethylene was used to cover the donor papillary muscle. In four valves the natural chordae tendineae at the anterior cusp were supported by two pairs of 5-0 expanded polytetrafluoroethylene sutures. At the beginning of the experiment two animals died early of valve incompetence. Another animal had to be put to death because of paraplegia after extracorporeal circulation and one died on postoperative day 41 of endocarditis. Six sheep were electively put to death, five after 153 +/- 8 days and one after 43 days. At the time of follow-up, a complete hemodynamic study including echocardiography and stress testing was performed. Heart rate at rest was 91 +/- 14 beats/min, left ventricular systolic pressure 96 +/- 20 mm Hg, left ventricular end-diastolic pressure 11 +/- 5 mm Hg, cardiac output 2.04 +/- 0.40 L/min, and the mean transvalvular pressure gradient was 4.9 +/- 2.8 mm Hg as measured by cardiac catheterization. Echocardiography showed excellent movement of all valve components. However, minor regurgitation was evident in one case. Gross morphologic characteristics showed good healing at the anulus and host papillary muscle; in one case there was a rupture of one small first-order chorda. On radiography no signs of calcification were evident. Light microscopy revealed minor to moderate collagen degeneration in all valve components. However, on electron microscopy the presence of numerous fibroblasts within the long-term implants indicated the biosynthesis of new collagen. In summary, allograft mitral valve replacement seems to be a promising procedure if the chordae tendineae are reinforced by expanding polytetrafluoroethylene sutures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Midterm results after stentless mitral valve replacement.

BACKGROUND To analyze the midterm clinical results after stentless mitral valve (SMV) replacement. METHODS AND RESULTS Fifty one patients (68.3+/-8.4 years, 35 female) with severe mitral valve disease (stenosis 25, incompetence 17, mixed lesion 9) received a chordally supported SMV (Quattro, St. Jude Medical Inc.) since August 1997. Preoperative New York Heart Association class was 3.1+/-0.6;...

متن کامل

Right sided heart evaluation after successful mitral valve replacement.

Introduction: It is well-documented that right-sided heart dysfunction and significant tricuspid valve regurgitation (TVR) have adverse effects on patient outcomes after left-sided heart valve surgery. Therefore, the evaluation of right ventriclular (RV) function and TR severity in patients who had undergone mitral valve replacement (MVR), associated with/without concomitant su...

متن کامل

High-risk Coronary Artery Bypass Grafting and Mitral Valve Replacement in a HIV Positive Patient

Certain subsets of high-risk mitral valve patients are not suitable candidates for transcatheter therapies. The objective of this report is to present a young patient with combined mitral valve and coronary artery disease to illustrate these challenges.In this report, we present a 47-year-old man with longstanding HIV infection who was referred with severe mitral regurgitation (MR) and profound...

متن کامل

دریچه میترال دو دهانه با تنگی شدید، یک مورد نادر

Double orifice mitral valve (DOMV) is an uncommon anomaly that was first described by Greenfield. Since then more than 200 cases have been reported. In this anomaly, mitral valve has a single fibrous annulus which opens with two openings into the left ventricle. We report a case of DOMV accompanied with severe stenosis in a 22-year old female who had complaints of moderate dyspnea. In transth...

متن کامل

Functional evaluation of the medtronic stentless porcine xenograft mitral valve in sheep.

BACKGROUND Recently, renewed interest in allograft and stentless "freehand" bileaflet xenograft mitral valve replacement has arisen. The variability of human papillary tip anatomy and scarcity of donors limit allograft availability, making xenograft mitral valves an attractive alternative; however, these valves require new surgical implantation techniques, and assessment of their hemodynamics a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of thoracic and cardiovascular surgery

دوره 111 3  شماره 

صفحات  -

تاریخ انتشار 1996