Biological variation in tPA-induced plasma clot lysis time.

نویسندگان

  • Simone Talens
  • Joyce J M C Malfliet
  • Goran Rudež
  • Henri M H Spronk
  • Nicole A H Janssen
  • Piet Meijer
  • Cornelis Kluft
  • Moniek P M de Maat
  • Dingeman C Rijken
چکیده

Hypofibrinolysis is a risk factor for venous and arterial thrombosis, and can be assessed by using a turbidimetric tPA-induced clot lysis time (CLT) assay. Biological variation in clot lysis time may affect the interpretation and usefulness of CLT as a risk factor for thrombosis. Sufficient information about assay variation and biological variation in CLT is not yet available. Thus, this study aimed to determine the analytical, within-subject and between-subject variation in CLT. We collected blood samples from 40 healthy individuals throughout a period of one year (average 11.8 visits) and determined the CLT of each plasma sample in duplicate. The mean (± SD) CLT was 83.8 (± 11.1) minutes. The coefficients of variation for total variation, analytical variation, within-subject variation and between-subject variation were 13.4%, 2.6%, 8.2% and 10.2%, respectively. One measurement can estimate the CLT that does not deviate more than 20% from its true value. The contribution of analytical variation to the within-subject variation was 5.0%, the index of individuality was 0.84 and the reference change value was 23.8%. The CLT was longer in the morning compared to the afternoon and was slightly longer in older individuals (> 40 years) compared to younger (≤40 years) individuals. There was no seasonal variation in CLT and no association with air pollution. CLT correlated weakly with fibrinogen, C-reactive protein, prothrombin time and thrombin generation. This study provides insight into the biological variation of CLT, which can be used in future studies testing CLT as a potential risk factor for thrombosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Biological Activity of Recombinant Reteplase Using Clot Lysis Time and Activated Partial Thromboplastin Time (APTT) Lysis Methods: A Comparative Study

Recombinant plasminogen activator (reteplase) is a third generation thrombolytic agent which has been used on coronary artery thrombosis and acute myocardial infarction. Clot lysis assay is usually considered as a unique method to evaluate biological activity of reteplase. In this study biological activity of reteplase was determined by APTT (activated partial thromboplastin time) lysis method....

متن کامل

بررسی تاثیر عناصر مس، روی و آلومینیوم بر شاخص‌های انعقاد و فیبرینولیز

Introduction: Myocardial infarction as a leading cause of death in most populations is associated with blood clot formation in coronary artery, and rapid clot lysis is important for patient treatment. Some reports have indicated the effects of some trace elements on blood coagulation and clot lysis. The aim of this study was to evaluate the effects of zinc, copper and aluminum on in-vitro coagu...

متن کامل

Determination of Biological Activity of Recombinant Reteplase Using Clot Lysis Time and Activated Partial Thromboplastin Time (APTT) Lysis Methods: A Comparative Study

Recombinant plasminogen activator (reteplase) is a third generation thrombolytic agent which has been used on coronary artery thrombosis and acute myocardial infarction. Clot lysis assay is usually considered as a unique method to evaluate biological activity of reteplase. In this study biological activity of reteplase was determined by APTT (activated partial thromboplastin time) lysis method....

متن کامل

Isoforms of apolipoprotein E can modulate tPA-induced clot lysis in vitro.

Apo E, and its respective isoforms, have been linked to outcome and survival in cerebral vascular and cardiovascular diseases. The effectiveness of intravenous tPA in patients with acute ischemic stroke appears to be enhanced in patients who have an Apo E2 phenotype. The ability of Apo E isoproteins (endogenous Apo E isoproteins or exogenous Apo E isoproteins) to modulate tPA-induced clot lysis...

متن کامل

Improvement of in vitro thrombolysis employing magnetically-guided microspheres.

Significant shortcomings in clinical thrombolysis efficiencies and arterial recanalization rates still exist to date necessitating the development of additional thrombolysis-enhancing technologies. For example, to improve tPA-induced systemic clot lysis several supplementary treatment methods have been proposed, among them ultrasound-enhanced tissue plasminogen activator (tPA) thrombolysis whic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Thrombosis and haemostasis

دوره 108 4  شماره 

صفحات  -

تاریخ انتشار 2012