Assessment of Peadiatric Radiation Dose from Routine X-Ray Examination: A Hospital Based Study, Taif Pediatric Hospital
نویسندگان
چکیده
Radiological imaging is an important part of today’s overall healthcare practicum, Imaging can begin as early as the first day of life but as children are more sensitive to radiation than adults special care should be in place. The main aim of the current study was to determine Entrance Surface Dose (ESD) to pediatric patients as the result of imaging procedure, in main pediatric hospital in Taif city –Saudi Arabia for the first time. 110 patients underwent different examinations (chest, abdomen, skull, and extremities), age range from 0-15 years .The patients biodata (age, weight, height, gender) were recorded. The exposure factors ,focal skin distance, tube output and back scatter factor were entered in special soft ware known by DOS CAL in order calculate the ESDs. The mean ESD obtained ranged 0.18 -0.32 mGy per radiograph for different ages and groups. No correlation coefficient was found between patient size (age or weight) and ESD, but significant correlation detected between ESD and tube potential difference (kV) encountered in these examinations. The results for pediatric radiation dose were agreed and compatible with literature. The radiation dose can be reduced more by optimization of each investigation and hence more studies is required for this task The results presented will serve as a baseline data needed for deriving local reference doses for pediatric X-ray examinations in this local department and hence it can be applied in the whole Kingdom.
منابع مشابه
Assessment of Pediatrics Radiation Dose from Routine X-Ray Examination at Jimma University Hospital, Southwest Ethiopia
Background Given the fact that children are more sensitive to ionizing radiation than adults, with an increased risk of developing radiation-induced cancer, special care should be taken when they undergo X-ray examinations. The main aim of the current study was to determine Entrance Surface Dose (ESD) to pediatric patients arising from routine x-ray examination in the Radiology Department of Ji...
متن کاملClinical Value of Low Dose CT- Scan in Pediatric Chest Diseases: Adequacy Assessment
Background Radiation dose about 400 times that of standard thoracic computed tomography (CT) in comparison with chest X- ray resulting in different approaches to decrease radiation dose have been established in the last few years to prevent possible side effects especially in children, such as low dose protocols. The aim of this study was assessment of clinical v...
متن کاملExcess Cancer Risk Assessment from Some Common X-Ray Examinations in Sabzevar County
Introduction: Nowadays ionizing radiation has a considerable contribution in medical diagnostic and treatment. Using ionizing radiation is increasing rapidly, so biological effects of ionizing radiation should be considered more. X-rays in the range of diagnostic radiology have hazardous effects and risks that are defined as random effects. These effects obey the LNT hypothesis that occur at lo...
متن کاملThe Evaluation of Conventional X-ray Exposure Parameters Including Tube Voltage and Exposure Time in Private and Governmental Hospitals of Lorestan Province, Iran
Introduction In radiography, dose and image quality are dependent on radiographic parameters. The problem is caused from incorrect use of radiography equipment and from the radiation exposure to patients much more than required. Therefore, the aim of this study was to implement a quality-control program to detect changes in exposure parameters, which may affect diagnosis or patient radiation do...
متن کاملEfficacy of Increasing Focus to Film Distance (FFD) for Patient’s Dose and Image Quality in Pediatric Chest Radiography
Background: Increasing the x-ray focus to film distance (FFD) has been advocated as an effective method to reduce the patients’ radiation dose. The aim of this study was to investigate the efficacy of this technique in patients' dose and image quality in pediatric chest x-ray.Material and methods: Sixty pediatric patients were x-ray imaged at FFDs of 100 and 130 cm. Dose measurements were perfo...