Diagnostic accuracy of mammography, clinical examination, US, and MR imaging in preoperative assessment of breast cancer.
نویسندگان
چکیده
PURPOSE To prospectively assess accuracy of mammography, clinical examination, ultrasonography (US), and magnetic resonance (MR) imaging in preoperative assessment of local extent of breast cancer. MATERIALS AND METHODS Institutional review board approval and informed patient consent were obtained. Results of bilateral mammography, US, and contrast-enhanced MR imaging were analyzed from 111 consecutive women with known or suspected invasive breast cancer. Results were correlated with histopathologic findings. RESULTS Analysis included 177 malignant foci in 121 cancerous breasts, of which 89 (50%) foci were palpable. Median size of 139 invasive foci was 18 mm (range, 2-107 mm). Mammographic sensitivity decreased from 100% in fatty breasts to 45% in extremely dense breasts. Mammographic sensitivity was highest for invasive ductal carcinoma (IDC) in 89 of 110 (81%) cases versus 10 of 29 (34%) cases of invasive lobular carcinoma (ILC) (P < .001) and 21 of 38 (55%) cases of ductal carcinoma in situ (DCIS) (P < .01). US showed higher sensitivity than did mammography for IDC, depicting 104 of 110 (94%) cases, and for ILC, depicting 25 of 29 (86%) cases (P < .01 for each). US showed higher sensitivity for invasive cancer than DCIS (18 of 38 [47%], P < .001). MR showed higher sensitivity than did mammography for all tumor types (P < .01) and higher sensitivity than did US for DCIS (P < .001), depicting 105 of 110 (95%) cases of IDC, 28 of 29 (96%) cases of ILC, and 34 of 38 (89%) cases of DCIS. In anticipation of conservation or no surgery after mammography and clinical examination in 96 breasts, additional tumor (which altered surgical approach) was present in 30. Additional tumor was depicted in 17 of 96 (18%) breasts at US and in 29 of 96 (30%) at MR, though extent was now overestimated in 12 of 96 (12%) at US and 20 of 96 (21%) at MR imaging. After combined mammography, clinical examination, and US, MR depicted additional tumor in another 12 of 96 (12%) breasts and led to overestimation of extent in another six (6%); US showed no detection benefit after MR imaging. Bilateral cancer was present in 10 of 111 (9%) patients; contralateral tumor was depicted mammographically in six and with both US and MR in an additional three. One contralateral cancer was demonstrated only clinically. CONCLUSION In nonfatty breasts, US and MR imaging were more sensitive than mammography for invasive cancer, but both MR imaging and US involved risk of overestimation of tumor extent. Combined mammography, clinical examination, and MR imaging were more sensitive than any other individual test or combination of tests.
منابع مشابه
Assessment of Computer Regulation Thermography (CRT) as a Complemetrary Diagnostic tool for Breast Cancer Patient
Background: Breast cancer is the most common type of cancer in women demanding accurate diagnosis to take remedial measures to treat.Objective: Comparing the diagnostic capability of the computer regulation thermography (CRT), as a novel and safe diagnostic procedure, with common methods including sonography, mammography and clinical examinations for diagnosing breast cancer in suspicious...
متن کاملDiagnostic Accuracy of Positron Emission Mammography with 18F-fluorodeoxyglucose in Breast Cancer Tumor of Less than 20 mm in Size
Objective(s): To investigate the diagnostic accuracy of positron emission mammography (PEM) and positron emission tomography/computed tomography (PET/CT) for small breast tumors of less than 20 mm in size.Methods: The study was conducted on a total of 100 subjects (i.e., 50 patients with pathologically proven breast cancer and 50 normal cases of medical screening). The total number of tumors wa...
متن کاملAccuracy of mammography, digital breast tomosynthesis, ultrasound and MR imaging in preoperative assessment of breast cancer.
AIM To define the accuracy of digital breast tomosynthesis (DBT) and magnetic resonance imaging (MRI) added to digital mammography (DM) and ultrasound (US) in the preoperative assessment of breast cancer. PATIENTS AND METHODS We performed a prospective study of 200 consecutive women with histologically-proven breast cancer using the above imaging techniques. Accuracy measurements were estimat...
متن کاملگزارش یک مورد کشف اتفاقی سرطان پستان در نمونه های پاتولوژی عمل جراحی مامو پلاستی کاهشی
Reduction mammaplasty is increasingly used for the treatment of discomfort associated with macromastia. Breast cancer is a tumor with the highest prevalence and incidence in women. As it can be expected, reduction mammaplasty specimens occasionally reveal breast cancer. So, before reduction mammaplasty, patients should be assessed for breast cancer risk and evaluated by physical examination a...
متن کاملMolecular imaging approaches in the diagnosis of breast cancer: A systematic review and meta-analysis
Introduction:The accuracy of positron emission tomography with computed tomography (PET/CT), positron emission mammography (PEM), and breast specific-gamma imaging (BSGI) in diagnosing breast cancer has never been systematically assessed, the present systematic review was aimed to address this issue. Methods:PubMed, Scopus and EMBASE were searched for st...