Rapid radioimmunoassay for corticotropin in unextracted human plasma.
نویسندگان
چکیده
This RIA for corticotropin (ACTH) involves use of a commercially available antiserum and permits measurement of immunoreactive ACTH in unextracted plasma. The assay takes 2.5 days, detects as little as 5 pg/mL of plasma, and is specific: structurally and (or) biosynthetically related peptides do not cross react. Generally, data on dilutions of almost all human plasma specimens produce curves parallel to that for the ACTH reference standard. Values correlate well with those obtained by a well-established but more laborious RIA. We measured immunoreactive ACTH in normal subjects at various times of the day and after modulation of their pituitary-adrenal axis, and in patients with hypo- and hyper-secretion of ACTH. We conclude that the full range of immunoreactive ACTH values, which accurately reflect the status of the subject's pituitary-adrenal axis, can be quickly and easily determined in samples of unextracted human plasma.
منابع مشابه
Measurement of corticotropin in unextracted plasma: comparison of a time-resolved immunofluorometric assay and an immunoradiometric assay, with use of the same monoclonal antibodies.
We describe a time-resolved immunofluorometric assay (IFMA) for corticotropin in unextracted human plasma, based on the use of two monoclonal antibodies: europium-labeled antibody 1A12 and antibody 2A3 coated onto microtiter wells. We compared the results of this assay with those of an immunoradiometric assay (IRMA) performed with the same antibodies working ranges (CV less than 10%) were 25 to...
متن کاملA direct radioimmunoassay for aldosterone in unextracted serum and plasma.
We describe a novel radioimmunoassay procedure for the direct estimation of aldosterone in unextracted plasma and serum samples, in which interfering binding proteins are digested by Proteinase K (Tritirachium alkaline proteinase, EC 3.4.21.14), a powerful proteolytic enzyme. Heating at 75 degrees C for 15 min inactivates the enzyme before radioimmunoassay. Alternatively, EDTA may be used to in...
متن کاملPlasma corticotropin radioimmunoassay, with use of fuller's earth for extraction.
A radioimmunoassay is described for plasma corticotropin whereby concentrationsover the range of 6 to 1000 ng/liter can be measured. Corticotropin extracted from plasma on fuller’s earth under carefully standardized conditions is assayed by a long-used double antibody radioimmunoassay procedure. Within (n = 6) and between (n = 12) assay precision is 39 ± 2 (SD) ng/liter and 44 ± 6 (SD) ng/liter...
متن کاملEvaluation of enzyme immunoassay and radioimmunoassay methods for the measurement of plasma oxytocin.
OBJECTIVE There is increased interest in measuring peripheral oxytocin levels to better understand the role of this peptide in mammalian behavior, physiology, and disease. The purpose of this study was to compare methods for plasma oxytocin measurement using a commercially available enzyme immunoassay (EIA) and radioimmunoassay (RIA), to evaluate the need for sample extraction, and to assess th...
متن کاملDirect measurement of testosterone in a pediatric center, with use of a radioimmunoassay kit and unextracted serum.
We evaluated a commercial (Radioassay Systems) radioimmunoassay kit for testosterone in which a double-antibody method and an 125I tracer are used. The 50-microL serum sample is assayed directly with no pre-extraction step. The assay system has good sensitivity (0.01 microgram/L), good precision (CV 5.2%), and little cross reactivity between testosterone and other androgens. Results compared we...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 30 2 شماره
صفحات -
تاریخ انتشار 1984