Asymmetric Limit Cycles in an Industrially Applied Controlled Resonant Converter

نویسندگان

  • Anders Hultgren
  • Jan Melin
چکیده

An industrially applied LCC power converter is modelled as a hybrid system. It is found that the hybrid system given a parameter set up and different initial conditions has three different limit cycles, one unstable and two asymmetric stable limit cycles. Effects of the asymmetric limit cycles are considered.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Voltage Regulation of DC-DC Series Resonant Converter Operating in Discontinuous Conduction Mode: The Hybrid Control Approach

Dynamic modeling and control of dc-dc series resonant converter (SRC) especially when operating in discontinuous conduction mode (DCM) is still a challenge in power electronics. Due to semiconductors switching, SRC is naturally represented as a switched linear system, a class of hybrid systems. Nevertheless, the hybrid nature of the SRC is commonly neglected and it is modeled as a purely contin...

متن کامل

An Efficient High-Step-Up Soft-Switching Boost Converter for Photovoltaic Application

In this paper an efficient high step-up converter with a coupled- inductor with soft- switching operation is presented. The proposed topology includes a coupled-inductor boost converter for raising the voltage gain. Moreover, a simple auxiliary resonant circuit composed of an auxiliary switch, a clamping diode and a resonant tank (inductor, capacitor), is adopted in this paper. The coupled-indu...

متن کامل

Control of Series Resonant Converter with Robust Performance Against Load and Power Circuit Components Uncertainties

Robust performance controller design for duty-cycle controlled series resonant converter (SRC) is proposed in this paper. The uncertainties of the converter are analyzed with load variation and power circuit components tolerances are taken into consideration. Additionally, a nominal performance (NP) controller is designed. Closed-loop system is simulated with Orcad and simulation results of r...

متن کامل

Resonant Parametric Perturbation Method to Control Chaos in Current Mode Controlled DC-DC Buck-Boost Converter

Abstract – Resonant parametric perturbation (RPP) method is an effective non-feedback method for controlling chaos. In this paper, the above method is applied for the current programmed buck-boost dc-dc converter which exhibits chaotic for wide parameter variations. The different possible operating regimes leading to chaotic operation of the current mode controlled buck-boost converter is discu...

متن کامل

High voltage gain DC-DC resonant converter

In this paper, a DC-DC resonant converter with high voltage gain and small size is studied. To reduce the size and weight of this converter, the operating frequency should be as high as possible. In this research, the frequency changes from 120 to 200 kHz. Due to the high operating frequency, it is necessary to reduce the switching losses using soft switching methods. Resonant converters are su...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009