Some factors affecting a commercial kit for radioimmunoassay of digoxin using tritiated digoxin.

نویسندگان

  • A B Boink
  • H H Kruyswijk
  • A F Willebrands
  • A H Maas
چکیده

Some factors affecting results of digoxin determinations using one commercially available radioimmunoassay kit are described and discussed. Serum of pregnant women, cord blood, amniotic fluid and serum of patients taking spironolactone may show erroneously high digoxin activity due to lack of specificity of the antiserum. Cross-reaction with digitoxin was found to vary substantially with antibody-lot. Haemaccel (5 g/1) in the sample leads to too low results. When ethanol (100 g/1) is present results are too high. The need for testing the specifity of every new lot of antiserum before use is stressed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of five radioimmunoassays and enzyme bioassay for measurement of digoxin in blood.

Digoxin-containing sera from 86 patients were analyzed for this drug by bioassay and radioimmunoassay. Each serum was analyzed in duplicate by six procedures: inhibition of Na+-K+-dependent ATPase and five "kit" radioimmunoassays from four different commercial sources. Mean values for two of the radioimmunoassays differed significantly from those for the bioassay. One radioimmunoassay mean valu...

متن کامل

Spurious underestimation of results for digoxin radioimmunoassay with a commercial kit.

Estimates of digoxin in serum with a commercial redioimmunoassay kit (Schwarz/Mann) occasionally result in more counts in the patient's "bound" fraction than in the "bound" fraction for the zero standard. This phenomenon has been investigated in 26 serum samples obtained from patients who were ingesting known amounts of digoxin. The problem appears to relate to environmental differences in at l...

متن کامل

Radioimmunoassay of digoxin: an intercomparison of results with three methods.

The radioimmunoassay of digoxin has been examined by comparing RIA data obtained by a clinical laboratory using the method of Smith et al. [New Engi. J. Med. 281, 1212 (1969)] with data obtained in a laboratory using commercially produced [3H]digoxin and [1251]digoxin kits. Correlations between clinical laboratory data and the results with each kit and correlation between kits are presented. Th...

متن کامل

A linear graph for digoxin radioimmunoassay.

The determination of drug or hormone concentrations by radioimmunoassay involves interpolation of values for radioisotope counts within standard curves, a technique which requires some dexterity in curve drawing and which results in some inaccuracy in practice. A number of linear transformations (Ekins, 1974) and computer programs (Burger et al, 1972; Duddleson et al, 1972; Livesey, 1974) for s...

متن کامل

Endogenous digoxin-like immunoreactive factors eliminated from serum samples by hydrophobic silica-gel extraction and enzyme immunoassay.

Elimination of endogenous digoxin-like immunoreactive factors (DLIF) that interfere with accurate measurement of digoxin requires use of a highly specific anti-digoxin antibody, or that DLIF be separated from digoxin before immunoassay. Several commercial digoxin-assay kits include a step for separating serum proteins and other substances from digoxin before immunoassay. We tested six different...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical chemistry and clinical biochemistry. Zeitschrift fur klinische Chemie und klinische Biochemie

دوره 15 5  شماره 

صفحات  -

تاریخ انتشار 1977