PURPOSE To compare the rotational stability and posterior capsule opacification (PCO) rate in eyes with a 1-piece or 3-piece acrylic intraocular lens (IOL). SETTING Department of Ophthalmology, Medical University of Vienna, Vienna, Austria. DESIGN Prospective randomized masked clinical trial. METHODS Patients with age-related cataract received a plate-haptic acrylic IOL (Acri.Smart 46S) in 1 eye and a 3-piece loop-haptic acrylic IOL (Acri.Lyc 53N) in the other eye. Retroillumination images were taken 1 hour, 1 week, and 1, 6, and 12 months postoperatively. Intraocular lens rotation was measured using standard software (Adobe Photoshop). The amount of PCO was assessed subjectively at the slitlamp and objectively using an automated image-analysis software (AQUA). RESULTS The study enrolled 80 eyes of 40 patients. The IOL rotation measurements showed excellent reproducibility, with a deviation of less than 0.8 degrees. Both IOLs had comparable and good rotational stability; rotation was less than 4 degrees in 71% of eyes 1 year postoperatively. The mean absolute rotation was 2.6 degrees ± 1.9 (SD) in the plate-haptic IOL group and 3.1 ± 2.4 degrees in the loop-haptic IOL group. The mean AQUA PCO score (scale 0 to 10) was 0.4 in both IOL groups (P = .7). CONCLUSION The 2 IOL models had comparable, excellent rotational stability and low PCO intensity 1 year postoperatively. Thus, the plate-haptic IOL may be a good platform for a toric model.
منابع مشابه
Comparison of Anterior Capsule Stability Following Implantation of Three Single Piece Acrylic Intraocular Lenses with Different Haptic Design
PURPOSE To compare the anterior capsule contraction and intraocular lens (IOL) decentration among three types of IOL to determine the influence of haptic design on anterior capsule stability. METHODS One hundred fifty patients were enrolled in this prospective, randomized study and 260 eyes underwent implantation of one of the following IOLs: modified L-haptic IOL (n = 74), modified C-haptic ...
متن کاملEffect of number and position of intraocular lens haptics on anterior capsule contraction: a randomized, prospective trial
BACKGROUND The present study aimed to evaluate the degree of anterior capsule contraction (capsulorhexis contraction) with three different single-piece, hydrophilic acrylic intraocular lenses (IOLs). METHODS Patients were prospectively randomized to be implanted with one of three types of IOLs during cataract surgery: the Ophtec Precizon (IOL A), the Lucid Korea Microflex (IOL B), and the Car...
متن کاملThe effects of three-piece or single-piece acrylic intraocular lens (IOL) implantation on posterior capsule opacification.
PURPOSE To evaluate the development of posterior capsule opacification (PCO) in patients implanted with 5.5 mm optics, single-piece or three-piece acrylic intraocular lens (IOL) in cataract surgery prospectively. METHODS This study was carried out on 267 eyes of 249 patients implanted with three-piece, 5.5 mm optics, acrylic IOL and 252 eyes of 244 patients implanted with single-piece, 5.5 mm...
متن کاملMalik`s Technique of Single Loop Fixation of Posterior Chamber Intraocular Lens in Presence of Partial Capsular Support.
Single loop fixation of posterior chamber intraocular lens in the presence of partial capsular support is usually performed by creation of additional scleral flap or tunnel. This extra port may expose the suture holding the intraocular lens or the tucked-in lens haptics to the outside environment thereby increasing the risk of endophthalmitis. We describe a technique of single loop fixation whe...
متن کاملEffect of four different intraocular lenses on posterior capsule opacification.
AIM To evaluate the impact of 4 different intraocular lenses (IOLs) on posterior capsule opacification (PCO) by comparing the neodymium: yttrium-aluminum-garnet (Nd:YAG) laser capsulotomy rates. METHODS This retrospective study included 4970 eyes of 4013 cataract patients who underwent phacoemulsification and IOL implantation between January 2000 and January 2008 by the same surgeon at one cl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of cataract and refractive surgery
دوره 37 2 شماره
صفحات -
تاریخ انتشار 2011