Comparison of the Performance of the TPTest, Tubex, Typhidot and Widal Immunodiagnostic Assays and Blood Cultures in Detecting Patients with Typhoid Fever in Bangladesh, Including Using a Bayesian Latent Class Modeling Approach

نویسندگان

  • Kamrul Islam
  • Md. Abu Sayeed
  • Emran Hossen
  • Farhana Khanam
  • Richelle C. Charles
  • Jason Andrews
  • Edward T. Ryan
  • Firdausi Qadri
چکیده

BACKGROUND There is an urgent need for an improved diagnostic assay for typhoid fever. In this current study, we compared the recently developed TPTest (Typhoid and Paratyphoid Test) with the Widal test, blood culture, and two commonly used commercially available kits, Tubex and Typhidot. METHODOLOGY For analysis, we categorized 92 Bangladeshi patients with suspected enteric fever into four groups: S. Typhi bacteremic patients (n = 28); patients with a fourfold change in Widal test from day 0 to convalescent period (n = 7); patients with Widal titer ≥1:320 (n = 13) at either acute or convalescent stage of disease; and patients suspected with enteric fever, but with a negative blood culture and Widal titer (n = 44). We also tested healthy endemic zone controls (n = 20) and Bangladeshi patients with other febrile illnesses (n = 15). Sample size was based on convenience to facilitate preliminary analysis. PRINCIPLE FINDINGS Of 28 S. Typhi bacteremic patients, 28 (100%), 21 (75%) and 18 (64%) patients were positive by TPTest, Tubex and Typhidot, respectively. In healthy endemic zone controls, the TPTest method was negative in all, whereas Tubex and Typhidot were positive in 3 (15%) and 5 (25%), respectively. We then estimated sensitivity and specificity of all diagnostic tests using Bayesian latent class modeling. The sensitivity of TPTest, Tubex and Typhidot were estimated at 96.0% (95% CI: 87.1%-99.8%), 60.2% (95% CI: 49.3%-71.2%), and 59.6% (95% CI: 50.1%-69.3%), respectively. Specificity was estimated at 96.6% (90.7%-99.2%) for TPTest, 89.9% (79.6%-96.8%) for Tubex, and 80.0% (67.7%-89.7%) for Typhidot. CONCLUSION These results suggest that the TPTest is highly sensitive and specific in diagnosing individuals with typhoid fever in a typhoid endemic setting, outperforming currently available and commonly used alternatives.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sensitivity and specificity of typhoid fever rapid antibody tests for laboratory diagnosis at two sub-Saharan African sites.

OBJECTIVE To evaluate three commercial typhoid rapid antibody tests for Salmonella Typhi antibodies in patients suspected of having typhoid fever in Mpumalanga, South Africa, and Moshi, United Republic of Tanzania. METHODS The diagnostic accuracy of Cromotest(®) (semiquantitative slide agglutination and single tube Widal test), TUBEX(®) and Typhidot(®) was assessed against that of blood cultu...

متن کامل

Original Article Evaluation of a newly developed ELISA against Widal, TUBEX-TF and Typhidot for typhoid fever surveillance

Introduction: Typhoid fever is endemic in many parts of the world and represents a major cause of acute febrile illness (AFI). Rapid and accurate laboratory methods for diagnosis of this disease are needed for both patient care and surveillance situations. Methodology: Serum samples were collected from AFI patients and used to evaluate the performance of a newly developed ELISA assay that uses ...

متن کامل

Evaluation of a newly developed ELISA against Widal, TUBEX-TF and Typhidot for typhoid fever surveillance.

INTRODUCTION Typhoid fever is endemic in many parts of the world and represents a major cause of acute febrile illness (AFI). Rapid and accurate laboratory methods for diagnosis of this disease are needed for both patient care and surveillance situations. METHODOLOGY Serum samples were collected from AFI patients and used to evaluate the performance of a newly developed ELISA assay that uses ...

متن کامل

Clinical and Laboratory Findings Including the Diagnostic Value of the Widal Test in Pediatric Cases of Typhoid Fever in Tehran

Background and Objective: The diagnosis of typhoid fever in children is a challenge due to the non-specific clinical picture. The current role of the Widal test for diagnosis in developing countries has not been clear. Materials and Methods: Charts were reviewed on all children ≤ 15 years of age discharg...

متن کامل

Evaluation of rapid diagnostic tests for typhoid fever.

Laboratory diagnosis of typhoid fever requires isolation and identification of Salmonella enterica serotype Typhi. In many areas where this disease is endemic, laboratory capability is limited. Recent advances in molecular immunology have led to the identification of sensitive and specific markers for typhoid fever and technology to manufacture practical and inexpensive kits for their rapid det...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2016