The changing landscape of brachytherapy for cervical cancer: a Canadian practice survey.

نویسندگان

  • T Phan
  • L Mula-Hussain
  • S Pavamani
  • A Pearce
  • D D'Souza
  • N G Patil
  • L Traptow
  • C M Doll
چکیده

BACKGROUND We documented changes in practice from 2009 to 2012 for cervical cancer brachytherapy in Canada. METHODS Centres with gynecologic brachytherapy services were sent an e-mail questionnaire querying their 2012 practice. Responses are reported and compared with practice patterns identified in a similar survey for 2009. RESULTS The response rate was 77% (24 of 31 centres). Almost all use high-dose-rate brachytherapy (92%); low-dose-rate brachytherapy has been completely phased out. Most continue to move patients from the site of applicator insertion to the radiation treatment simulation suite (75%) or to a diagnostic imaging department (29%), or both. In 2012, the imaging modalities used for dose specification were computed tomography [ct (75%)], magnetic resonance imaging [mri (38%)], plain radiography (21%), and cone-beam ct (8%). The number of institutions using mri guidance has markedly increased during the period of interest (9 vs. 1). Most respondents (58% vs. 14%) prescribed using guidelines from the Groupe Européen de Curiethérapie and the European Society for Therapeutic Radiology and Oncology, but they also used point A as a reference. Commonly used high-dose radiation regimens included 30 Gy in 5 fractions and 24 Gy in 3 fractions. CONCLUSIONS In Canada, image-guided brachytherapy for cervical cancer continues to evolve. Although ct-based imaging remains the most commonly used modality, many centres have adopted mri for at least 1 brachytherapy treatment. More centres are using fewer fractions and a slightly lower biologically effective dose, but are still achieving EQD2 (2-Gy equivalent) doses of 80-90 Gy in combination with external-beam radiation therapy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluating variation of Hot Spot Location in order to radiobiological calculation of Organ at Risk in High-dose- rate Brachytherapy of Cervical Cancer

Introduction: Gynecological malignancies present challenges in determining an appropriate volumetric dose due to the highly variable physiologic activity of the surrounding tissue. Because of the high doses used in brachytherapy, surrounding structures have the potential to move around in the dose region and receive unknown amounts of radiation. Calculating hotspot region from ...

متن کامل

Out-Of-Field Dose Measurement and Second Cancer-Risk Estimation Following External Beam Radiotherapy and Brachytherapy for Cervical Cancer Treatment: A Phantom Study

Introduction: The present study aimed to measure the scatter and leakage dose received by out-of-field organs while delivering Radiotherapy (RT) treatment of cervical cancer. Moreover, this study estimated the risk of second cancer (SC). The doses to out-of-field organs were measured using a lithium fluoride (TLD 100) dosimeter while delivering External Beam Radiothera...

متن کامل

Rectal and Bladder Dose Measurements in the Intracavitary Applications of Cervical Cancer Treatment with HDR Afterloading System: Comparison of TPS Data with MOSFET Detector

Background: Intracavitary brachytherapy plays a major role in management of cervical carcinoma. Assessment of dose received by OAR’s therefore becomes crucial for the estimation of radiation toxicities in HDR brachytherapy. Objective: Purpose of this study is to evaluate the role of in vivo dosimetry in HDR brachytherapy and to compare actual doses delivered to OAR’ s with those calculate...

متن کامل

”Maximum dose” points in cervical and endometrial cancer medium dose rate brachytherapy

Background: Best dose distribution in target volume and control of Organ at Risk (OAR) dose are the two main goals in brachytherapy. Materials and Methods: In this study in vivo dosimetry in 4 rectal points was performed by Transillumination Dosimeter (TLD) s and the measured doses were compared in different patients. One point was reported to have the maximum dose in each patient and the very ...

متن کامل

Comparison the treatment time of cobalt and iridium sources in HDR brachytherapy

Introduction: The use of long-half-life Cobalt source instead of iridium source will be very helpful in HDR brachytherapy for treatment of cervical cancer. The aim of this study was compared the treatment time with cobalt and iridium source in brachytherapy for treatment of cervical cancer using Tandem-ovoid applicator. Materials and Methods: In this study, 19...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Current oncology

دوره 22 5  شماره 

صفحات  -

تاریخ انتشار 2015