Multiparametric Flow System for the Automated Determination of Sodium, Potassium, Calcium, and Magnesium in Large-Volume Parenteral Solutions and Concentrated Hemodialysis Solutions
نویسندگان
چکیده
A multiparametric flow system based on multicommutation and binary sampling has been designed for the automated determination of sodium, potassium, calcium, and magnesium in large-volume parenteral solutions and hemodialysis concentrated solutions. The goal was to obtain a computer-controlled system capable of determining the four metals without extensive modifications. The system involved the use of five solenoid valves under software control, allowing the establishment of the appropriate flow conditions for each analyte, that is, sample size, dilution, reagent addition, and so forth. Detection was carried out by either flame atomic emission spectrometry (sodium, potassium) or flame atomic absorption spectrometry (calcium, magnesium). The influence of several operating parameters was studied. Validation was carried out by analyzing artificial samples. Figures of merit obtained include linearity, accuracy, precision, and sampling frequency. Linearity was satisfactory: sodium, r2>0.999 (0.5-3.5 g/L), potassium, r2>0.996 (50-150 mg/L), calcium, r2>0.999 (30-120 mg/L), and magnesium, r2>0.999 (20-40 mg/L). Precision (sr, %, n=5) was better than 2.1%, and accuracy (evaluated through recovery assays) was in the range of 99.8%-101.0% (sodium), 100.8-102.5% (potassium), 97.3%-101.3% (calcium), and 97.1%-99.8% (magnesium). Sampling frequencies (h-1) were 70 (sodium), 75 (potassium), 70 (calcium), and 58 (magnesium). According to the results obtained, the use of an automated multiparametric system based on multicommutation offers several advantages for the quality control of large-volume parenteral solutions and hemodialysis concentrated solutions.
منابع مشابه
Possible Incompatibility between Amino Acids and Copper in Solutions for Pediatric Parenteral Nutrition.
The nutrient formulas used for parenteral nutrition are highly complex admixtures of multiple solutions, infused by the IV route to patients who are unable to receive nutrition by mouth or by the enteral route. The administered products contain macronutrients (amino acids, dextrose, and lipids), electrolytes (sodium, potassium, calcium, phosphate, magnesium, chloride, and acetate), micronutrien...
متن کاملApplication of the 1,2-Dihydroxybenzene-3,5-Disulfonic Acid for Separation and Preconcentration of Trace Iron and Determination by Eight Order Derivative Spectrophotometry
Iron is quantitatively retained on an adsorbent made by coprecipitation of 1,2-dihydroxybenzene-3,5-disulfonic acid (Tiron) and tetradecyldimethylbenzylammonium choride (TDBA) an microcrystalline naphthalene as a slurry or packed in a column, in the pH range 6.0-9.0 from a large volumes of aqueous solutions (up to 200 ml on microcrystalline naphthalene and up to 500 ml of aqueous solutions ...
متن کاملAdministration of Large Volume Hypertonic Solutions for Resuscitation of Hemorrhagic Shock in Rabbit
An animal model was designed to study the effect of large volume Hypertonic Solutions (HTS) for resuscitation following a hypovolemic shock. Resuscitation in hypovolemic animals was performed by infusion of 15 ml/kg of normal saline (group I), 5% sodium bicarbonate (NaHCO3) (group II), 5% sodium chloride (NaCI) and 7.5 % NaHCO3 1:1 VN (group III), 5% NaC1 (group IV), and 5% NaCl and 5% serum a...
متن کاملVerification of Measurement Capabilities of Flame Atomic Spectrometry for the Determination of Sodium, Potassium, Magnesium, and Calcium in Natural Fresh Water Part I. Comparison of Recommended Methods
Current Polish Standard methods for the determination of sodium, potassium, magnesium, and calcium in natural fresh water were compared with other official standards, mostly from the U.S. (ASTM, USEPA, USGS), regarding recommended top concentrations of measured elements in measured solutions and methods of regulating the sensitivity of measurements. Some of the disadvantageous limitations of co...
متن کاملDetermination of some seminal plasma indices, sperm density and sperm motility in the Persian sturgeon Acipenser persicus
Some biological aspects of semen were investigated in the Persian sturgeon, Acipenser persicus, by determination of seminal plasma indices (ionic composition and osmolality), sperm density and their relationships with sperm motility. The osmolality of seminal plasma ranged from 42.00 to 111.00 mOsmol Kg-1. The concentrations of Sodium (Na+), Potassium (K+), Chloride (Cl-), Calcium (Ca2+) and Ma...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of Automated Methods & Management in Chemistry
دوره 2006 شماره
صفحات -
تاریخ انتشار 2006