In-vivo analysis of epicutaneous pressure distribution beneath a femoral tourniquet – an observational study
نویسندگان
چکیده
BACKGROUND Compression of the tissue beneath tourniquets used in limb surgery is associated with varying degrees of soft tissue damage. The interaction between fluids and applied pressure seems to play an important role in the appearance of skin lesions. The extent of the transfer of force between the tourniquet and the skin, however, has yet to be studied. The aim of the present study was to quantify in-vivo the transfer of pressure between a tourniquet and the skin of the thigh. METHODS Pressure under the tourniquet was measured using sensors in 25 consecutive patients over the course of elective surgical procedures. Linear mixed modeling was used to assess the homogeneity of the distribution of pressure around the circumference of the limb, variation in pressure values over time, and the influence of limb circumference and the Body-Mass-Index (BMI) on pressure transfer. RESULTS Mean pressure on the skin was significantly lower than the inner pressure of the cuff (5.95%, 20.5 ± 9.36 mmHg, p < 0.01). There was a discrete, but significant (p < 0.001) increase in pressure within the first twenty minutes after inflation. Sensors located in the area of overlap of the cuff registered significantly higher pressure values (p < 0.01). BMI and leg circumference had no influence on the transfer of pressure to the surface of the skin (p = 0.88 and p = 0.51). CONCLUSIONS Pressure transfer around the circumference of the limb was distributed inhomogeneously. The measurement series revealed a global pressure drop compared to the initial pressure of the cuff. No relationship could be demonstrated between the pressure transferred to the skin and the BMI or limb circumference.
منابع مشابه
Comparison of the effectiveness of tourniquet and Valsalva maneuver in relieving pain caused by propofol injection to induce general anesthesia: A double-blind randomized clinical trial
Introduction: Propofol is one of the most common anesthetic drugs. Painful injection with a reported prevalence of 28 to 90% in various studies is one of the problems of taking Propofol. The present study investigated the effect of performing the Valsalva maneuver and tourniquet twisting on pain intensity and hemodynamic changes. Materials and Methods: This clinical trial was performed on 105 p...
متن کاملTourniquet-Related Iatrogenic Femoral Nerve Palsy after Knee Surgery: Case Report and Review of the Literature
Purpose. Tourniquet-induced nerve injuries have been reported in the literature, but even if electromyography abnormalities in knee surgery are frequent, only two cases of permanent femoral nerve palsies have been reported, both after prolonged tourniquet time. We report a case of tourniquet-related permanent femoral nerve palsy after knee surgery. Case Report. We report a case of a 58-year-old...
متن کاملOcclusion of arterial flow in the extremities at subsystolic pressures through the use of wide tourniquet cuffs.
Tourniquet-induced peripheral neuropathy is at least partially attributable to excessive forces applied to the nerves beneath cuffs inflated to high pressures. Lowering the inflation pressure to the minimum necessary to obtain an effective arrest of blood flow distal to the tourniquet cuff should increase the safety of these systems. Tourniquet cuffs with widths varying from 4.5 cm to 80 cm wer...
متن کاملSurgical tourniquets in orthopaedics.
Higher levels of tourniquet pressure and higher pressure gradients beneath tourniquet cuffs are associated with a higher risk of nerve-related injury. Measurement of limb occlusion pressure can help to minimize tourniquet pressure levels and pressure gradients for individual patients and individual surgical procedures. Selective use of pneumatic, wider, and contoured tourniquet cuffs reduces to...
متن کاملPerineural pressures under the pneumatic tourniquet in the upper extremity.
The literature indicates that tourniquet-induced neurological injuries are relatively common and frequently occur at a subclinical level. In order to evaluate the pressure transmitted to the major peripheral nerves of the arm by an externally applied pneumatic tourniquet, a fully implantable biomedical pressure transducer was placed adjacent the radial, median and ulnar nerves in six cadaver up...
متن کامل