A new method to determine cortical bone thickness in CT images using a hybrid approach of parametric profile representation and local adaptive thresholds: Accuracy results

نویسندگان

  • Oleg Museyko
  • Bastian Gerner
  • Klaus Engelke
چکیده

MOTIVATION Cortical bone is an important contributor to bone strength and is pivotal to understand the etiology of osteoporotic fractures and the specific mechanisms of antiosteoporotic treatment regimen. 3D computed tomography (CT) can be used to measure cortical thickness, density, and mass in the proximal femur, lumbar vertebrae, and distal forearm. However, the spatial resolution of clinical whole body CT scanners is limited by radiation exposure; partial volume artefacts severely impair the accurate assessment of cortical parameters, in particular in locations where the cortex is thin such as in the lumbar vertebral bodies or in the femoral neck. METHOD Model-based deconvolution approaches recover the cortical thickness by numerically deconvolving the image along 1D profiles using an estimated scanner point spread function (PSF) and a hypothesized uniform cortical bone mineral density (reference density). In this work we provide a new essentially analytical unique solution to the model-based cortex recovery problem using few characteristics of the measured profile and thus eliminate the non-linear optimization step for deconvolution. Also, the proposed approach allows to get rid of the PSF in the model and reduces sensitivity to errors in the reference density. Additionally, run-time and memory effective computation of cortical thickness was achieved with the help of a lookup table. RESULTS The method accuracy and robustness was validated and compared to that of a deconvolution approach recently proposed for cortical bone and of the 50% relative threshold technique: in a simulated environment with noise and various error levels in the reference density and using CT acquisitions of the European Forearm Phantom (EFP II), a modification of a widely used anthropomorphic standard of cortical and trabecular bone compartments that was scanned with various scan protocols. CONCLUSION Results of simulations and of phantom data analysis verified the following properties of the new method: 1) Robustness against errors in the reference density. 2) Excellent accuracy on ground truth data with various noise levels. 3) Very fast computation using a lookup table.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of state-of-the-art atlas-based bone segmentation approaches from brain MR images for MR-only radiation planning and PET/MR attenuation correction

Introduction: Magnetic Resonance (MR) imaging has emerged as a valuable tool in radiation treatment (RT) planning as well as Positron Emission Tomography (PET) imaging owing to its superior soft-tissue contrast. Due to the fact that there is no direct transformation from voxel intensity in MR images into electron density, itchr('39')s crucial to generate a pseudo-CT (Computed Tomography) image ...

متن کامل

New Pseudo-CT Generation Approach from Magnetic Resonance Imaging using a Local Texture Descriptor

Background: One of the challenges of PET/MRI combined systems is to derive an attenuation map to correct the PET image. For that, the pseudo-CT image could be used to correct the attenuation. Until now, most existing scientific researches construct this pseudo-CT image using the registration techniques. However, these techniques suffer from the local minima of the non-rigid deformation energy f...

متن کامل

Mandibular Trabecular Bone Analysis Using Local Binary Pattern for Osteoporosis Diagnosis

Background: Osteoporosis is a systemic skeletal disease characterized by low bone mineral density (BMD) and micro-architectural deterioration of bone tissue, leading to bone fragility and increased fracture risk. Since Panoramic image is a feasible and relatively routine imaging technique in dentistry; it could provide an opportunistic chance for screening osteoporosis. In this regard, numerous...

متن کامل

بررسی ویژگی‌های روان‌سنجی نیم‌رخ حسی دان فرم مدرسه

Objective Sensory processing refers to reception, adjustment, and integration of sensory information sequentially and generates adaptive responses. People need to have appropriate sensory processing abilities for functioning adequately in the environment and be able to participate in activities of daily living. Dunn's sensory processing model consists of two constructions. The first constructio...

متن کامل

Harmonics Estimation in Power Systems using a Fast Hybrid Algorithm

In this paper a novel hybrid algorithm for harmonics estimation in power systems is proposed. The estimation of the harmonic components is a nonlinear problem due to the nonlinearity of phase of sinusoids in distorted waveforms. Most researchers implemented nonlinear methods to extract the harmonic parameters. However, nonlinear methods for amplitude estimation increase time of convergence. Hen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017