Comparison of patient's preference, pain perception, and usability between Micro Fine Plus 31-gauge needle and Microtapered NanoPass 33-gauge needle for insulin therapy.
نویسندگان
چکیده
BACKGROUND How smoothly insulin is injected is one of the major concerns when patients commence insulin injection therapy. Improving its usability may be important in initiation therapy and adherence, resulting in clinical benefits to the patient. METHODS In a single-center, open-label and randomized two-period crossover trial, the effect of the tapered needle of NanoPass (33 gauge, 5 mm) on usability in comparison with the standard needle of Micro Fine Plus (31 gauge, 5 mm) was examined using a questionnaire. Patients with insulin-dependent diabetes (n = 40, self-injecting insulin four times daily for more than 3 months) were randomized to use NanoPass or Micro Fine Plus needles for 1 week and then use the alternative for 1 week. Patients completed the questionnaire before and after each test week. Each evaluation was scored from -100 (worst) to +100 (best) by a visual analogue scale. A higher score indicated a more favorable outcome compared with the other needle. RESULTS The NanoPass needle was significantly less painful to insert and caused less bruising than the Micro Fine Plus needle. However, there was no significant difference in the overall patient satisfaction score between the two needles. Meanwhile, the NanoPass needle, which had less resistance in insertion with a new lubricant coating method, had a significantly superior (P < 0.001) overall patient's satisfaction score, including less frightening use, less bleeding, and less dribbling of injected insulin in comparison with the former evaluation. CONCLUSIONS For overall patient satisfaction in using an insulin needle, developing a thinner needle and improving other factors, such as lubricity coating the needle, are important.
منابع مشابه
Comparison of Inferior Dental Nerve Block Injections in Child Patients Using 30-Gauge and 27-Gauge Short Needles
Introduction: The purpose of the present study was to record their pain sensation and to assess children`s reaction objectively and subjectively while receiving dental local anesthesia with 27- and 30-gauge needles. Methods: Forty children (24 boys and 16 girls) participated in this study. A random double-blinded crossover design was used so that each child served as his or her own control, rec...
متن کاملVacuum-assisted breast biopsy: A comparison of 11-gauge and 8-gauge needles in benign breast disease
BACKGROUND Minimal invasive breast biopsy is standard care for the diagnosis of suspicious breast lesions. There are different vacuum biopsy (VB) systems in use. The aim of the study was to determine the differences between the 8-gauge and the 11-gauge needle with respect to a) diagnostic reliability, b) complication rate and c) subjective perception of pain when used for vacuum-assisted breast...
متن کاملImpact of a modified needle tip geometry on penetration force as well as acceptability, preference, and perceived pain in subjects with diabetes.
BACKGROUND Multiple factors impact subcutaneous insulin injection pain. Injection devices [e.g., syringe or pen needle (PN)] affect pain due to needle length, diameter, needle polishing and lubrication, and needle tip geometry. METHODS We evaluated a modified 5-bevel PN tip in 32 G × 4 mm 31 G × 5 mm and 8 mm PNs vs the equivalent marketed 3-bevel PNs in laboratory penetration force testing, ...
متن کاملRecognition of and steps to mitigate anxiety and fear of pain in injectable diabetes treatment
Injectable treatments, such as glucagon-like peptide-1 receptor agonists and insulin, are options for the pharmacologic treatment of type 2 diabetes. Numerous barriers lead to delay in initiating injectable treatment, which, in turn, may lead to inadequate glycemic control and increased risk of diabetes-related complications, underscoring the need to understand and address these barriers. Barri...
متن کاملSteroid hormone receptors, MIB-1, p53, and c-erb-B2 expression on breast cancer: Comparison of immunohistochemistry on cell block and fine needle aspiration and tissue sample, in northwest Iran
Background: Fine-needle aspiration of breast cancer often provides moderate cellular material that is representative of the tumors. These samples can be used not only for cytological diagnosis but also to obtain information on the prognosis and likely response to therapy by using immunohistochemical staining studies. Methods: We assessed the degree of correlation between prognostic biologic ma...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of diabetes science and technology
دوره 1 5 شماره
صفحات -
تاریخ انتشار 2007