[frontal, Axillary and Tympanic Temperature Measurements in Children].
نویسندگان
چکیده
The purpose of this study was to compare the results of body temperature measurements obtained by standard axillary thermometers with the results of infrared tympanic and frontal skin thermometry in afebrile children. This study comprises a single-center, prospective comparison trial. A total of 345 afebrile children aged 4 to 16 years hospitalized in the pediatric surgery department for elective surgery were included. One thousand axillary, tympanic and frontal measurements were obtained and compared. We used two different infrared thermometers in this study; one type measured the tympanic temperature, the other the temperature on the forehead. The axillary temperature measured with the glass thermometer was set as the standard. Each patient was exposed to a constant environmental temperature for a minimum of 10 min before simultaneous temperature measurements. The mean-frontal temperature 36.9 ± 0.38 °C was equal to the axillary temperature 36.9 ± 0.16 °C. The mean tympanic temperature was 36.3 ± 0.98 °C. The mean difference between the tympanic and axillary temperatures was -0.4 °C. The tympanic temperature had a threefold greater dispersion than frontal and a fivefold greater dispersion than axillary temperature. The results of this study suggest that the axillary temperature measured with glass thermometer has the least dispersion. Somewhat less reliable is the frontal temperature measured with infrared thermometer. The least reliable is tympanic temperature measurement.
منابع مشابه
Comparison of Axillary and Tympanic Temperature Measurements in Children Diagnosed with Acute Otitis Media
Background. Acute otitis media [AOM] may affect the accuracy of tympanic temperature measurements. We aimed to compare tympanic temperature measurements in patients with AOM against control groups, as well as compare the tympanic temperatures with axillary thermometry. Methods. This is a prospective, observational study. Patients from pediatric outpatient and emergency clinics who were diagnose...
متن کاملA Comparative Study on Temperature Accuracy between Tympanic, Rectal, and Axillary Sites
A new method recently used for measuring the temperature is using tympanic thermometer. The aim of this study was to compare the accuracy of this method with rectal and axillary measurement in children less than 6 years old. A total of 220 pair ears, axillaries, and rectal sites were used to determine the body temperature in patients aged between 3 months to 6 years who referred to Emergency De...
متن کاملAn evaluation of tympanic thermometry in a paediatric emergency department.
BACKGROUND AND OBJECTIVES The consequences of missing fever in children can be grave. Body temperature is commonly recorded at the axilla but accuracy is a problem. This study aimed to evaluate the accuracy of a tympanic thermometer in the paediatric emergency setting. METHOD In a total of 106 infants, the body temperature was measured in the daytime with an infrared tympanic thermometer, and...
متن کاملAxillary and tympanic membrane temperature measurements are unreliable early after cardiopulmonary bypass.
BACKGROUND AND OBJECTIVE Inaccurate measurements of body temperature following cardiopulmonary bypass may be associated with serious complications. The purpose of this study was to determine whether axillary and tympanic temperature measurements correlate with the urinary bladder temperature in the early postcardiac surgery period. METHODS Forty-nine adult patients who underwent cardiac surge...
متن کاملAural and Nasal Temperature Measurements Using an Infrared Thermometer vs Conventional Axillary and Oral Measurements
Introduction and Aim: The aim of the present study was to compare aural temperature measurements with conventional methods (axillary and oral) in patients with unilateral tympanic membrane perforation or myringosclerosis. The study also aimed to test the potential nasal use of infrared thermometer. Materials and Methods: Forty-four adult patients with monoaural tympanic membrane perforation and...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Lijecnicki vjesnik
دوره 138 1-2 شماره
صفحات -
تاریخ انتشار 2016