Effect of Proximal Anastomotic Diameter on Venous Bypass Graft Patency in Patients Undergoing Coronary Artery Bypass Grafting.

نویسندگان

  • Mehmet Kaya
  • Taner İyigün
  • Mugisha Kyaruzi
  • Okan Akıncı
  • Hafize Otcu
  • Mehmet Gül
  • Aydın Rodi Tosu
  • Mehmet Yeniterzi
چکیده

BACKGROUND In this study, the relationship between patency of saphenous vein (SV) graft and different sizes of aorta wall punches was investigated during the follow-up period after coronary artery bypass graft surgery. We also evaluated the other possible factors affecting SV graft patency. METHODS This study consisted of 266 consecutive and symptomatic patients with postoperative angiography. The primary endpoint was at least one saphenous graft failure observed from coronary computed tomography angiography (cCTA) and/or invasive angiography after surgery. Groups were created as SV occluded and patent group. Survival curves of patients in groups were estimated using Kaplan-Meier method and compared by log-rank test. Multivariate analysis was performed using the Cox proportional hazard model. RESULTS Cox-regression analysis demonstrated influence of older age (P = .023) and Diabetes Mellitus (DM) (P = .002) on SV graft failure. However, increasing ejection fraction (P = .011) was a protective factor against SV graft failure. There was no significant difference between the two groups in terms of usage rate of the punches with different diameters (P = .296). CONCLUSION The incidence of SV graft patency does not seem to increase in patients whose 4.8-mm aortic punch was used during proximal anastomosis compared to the reference group in which a punch of 4.0 mm was used. Also, the final proximal anastomosis graft size that was measured using cCTA was similar between patients with 4.8-mm punch and patients with 4-mm punch. Results from this study could help to determine which size for aortosaphenous anastomosis is clinically optimal.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Study of coronary artery bypass using the PAS-Port device: assessment by multidetector computed tomography.

OBJECTIVE The use of automatic anastomotic devices in coronary artery bypass grafting surgery is associated with lower patency rates in comparison to conventional anastomosis methods. This is thought to be caused by graft curvature occurring after closing of the chest wall. METHODS We evaluated 39 grafts in 28 patients who underwent off-pump coronary artery bypass surgery using the PAS-Port. ...

متن کامل

Impact of Patient and Target-Vessel Characteristics on Arterial and Venous Bypass Graft Patency Insight From a Randomized Trial

Background—The purpose of this investigation was to determine optimal patient and target-vessel characteristics to maximize arterial and venous graft patency on the basis of data from a large clinical trial. Methods and Results—Angiographic data on 440 radial artery grafts and 440 saphenous vein grafts were analyzed with methodology to account for within-patient clustering. Multivariable models...

متن کامل

Use of skeletonized radial artery graft with the PAS-Port proximal anastomotic device.

PURPOSE We report our initial experience with the PAS-Port proximal anastomosis system (Cardica Inc, Redwood City, CA) using full-skeletonized radial artery (RA) in patients requiring off-pump coronary artery bypass grafting. DESCRIPTION The PAS-Port system (Cardica Inc) was used in 25 patients undergoing off-pump coronary artery bypass surgery. All patients received at least one RA graft usi...

متن کامل

Comparing Effects of Continuous Insulin Infusion with or without Subcutaneous Glargine Insulin on Glycemic Control in Diabetic Patients Undergoing Coronary Artery Bypass Graft (CABG)

OBJECTIVE: Hyperglycemia is associated with increased morbidity and mortality in diabetic patients following coronary artery bypass grafting. Tight glycemic control in perioperative period can reduce these events. The goal of this study was to determine whether combination of continuous infusion and subcutaneous glargine as a basal insulin could improve glycemic control. MATERIAL AND METHODS:...

متن کامل

Letter by Spence et al regarding article, "Impact of patient and target-vessel characteristics on arterial and venous bypass graft patency: insight from a randomized trial".

BACKGROUND The purpose of this investigation was to determine optimal patient and target-vessel characteristics to maximize arterial and venous graft patency on the basis of data from a large clinical trial. METHODS AND RESULTS Angiographic data on 440 radial artery grafts and 440 saphenous vein grafts were analyzed with methodology to account for within-patient clustering. Multivariable mode...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The heart surgery forum

دوره 18 5  شماره 

صفحات  -

تاریخ انتشار 2015