Pool boiling experiments were conducted with three horizontal, flat, silicon surfaces, two of which were coated with vertically aligned multiwalled carbon nanotubes (MWCNTs). The two wafers were coated with MWCNT of two different thicknesses: 9 m (Type-A) and 25 m (Type-B). Experiments were conducted for the nucleate boiling and film boiling regimes for saturated and subcooled conditions with liquid subcooling of 0–30°C using a dielectric fluorocarbon liquid (PF-5060) as test fluid. The pool boiling heat flux data obtained from the bare silicon test surface were used as a base line for all heat transfer comparisons. Type-B MWCNT coatings enhanced the critical heat flux (CHF) in saturated nucleate boiling by 58%. The heat flux at the Leidenfrost point was enhanced by a maximum of 150% (i.e., 2.5 times) at 10°C subcooling. Type-A MWCNT enhanced the CHF in nucleate boiling by as much as 62%. Both Type-A MWCNT and bare silicon test surfaces showed similar heat transfer rates (within the bounds of experimental uncertainty) in film boiling. The Leidenfrost points on the boiling curve for Type-A MWCNT occurred at higher wall superheats. The percentage enhancements in the value of heat flux at the CHF condition decreased with an increase in liquid subcooling. However the enhancement in heat flux at the Leidenfrost points for the nanotube coated surfaces increased with liquid subcooling. Significantly higher bubble nucleation rates were observed for both nanotube coated surfaces. DOI: 10.1115/1.3000595

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

of Heat Transfer Technical Brief ool Boiling Experiments on ultiwalled Carbon Nanotube

n this study, two silicon wafer substrates were coated with vertially aligned multiwalled carbon nanotubes (MWCNT) “forests” nd were used for pool boiling studies. The MWCNT forests (9 nd 25 m in height) were synthesized on the silicon wafer subtrates using chemical vapor deposition (CVD) process. The subtrates were clamped on a cylindrical copper block with embeded cartridge heaters. The heat ...

متن کامل

Pool Boiling Performance Comparison of Smooth and Sintered Copper Surfaces with and without Carbon Nanotubes

Pool boiling heat transfer is measured with two individual working fluids on copper surfaces enhanced with sintered copper powder and carbon nanotubes. The working fluids are a segregated hydrofluoroether, HFE-7300, and deionized water. The surfaces considered in the experiments include smooth copper, copper with sintered copper particles, smooth copper with copper-coated carbon nanotubes (CNT)...

متن کامل

Numerical Simulation and Experimental Validation of the Dynamics of a Single Bubble During Pool Boiling Under Constant and Time-Varying Reduced Gravity Conditions

The numerical simulation and experimental validations of the growth and departure of a single bubble on a horizontal heated surface during pool boiling under reduced gravity conditions have been performed here. A finite difference scheme is used to solve the equations governing mass, momentum and energy in the vapor liquid phases. The vaporliquid interface is captured by level set method, which...

متن کامل

Non-linear dynamical analyses of transient surface temperature fluctuations during subcooled pool boiling on a horizontal disk

0017-9310/$ see front matter 2009 Elsevier Ltd. A doi:10.1016/j.ijheatmasstransfer.2009.06.023 * Corresponding author. Tel.: +1 979 845 4500; fax E-mail address: [email protected] (D. Banerjee The class of dynamics in pool boiling on a large-size heater is assessed under subcooled pool boiling conditions. Transient surface temperature measurements are obtained using surface micro-machined K-ty...

متن کامل

Pool boiling heat transfer on small heaters: effect of gravity and subcooling

Measurements of space and time resolved subcooled pool boiling of FC-72 in low, earth, and high gravity environments were made using a microscale heater array. Data from each heater in the array were synchronized with highspeed digital video. The boiling behavior was dominated by the formation of a large primary bubble on the surface which acted as a ‘‘sink’’ for many smaller bubbles surroundin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009