Influence of proteins from physiological solutions on the electrochemical behaviour of the Ti-6Al-4V alloy: reproducibility and time-frequency dependence. ---- Influence de la teneur en prot\'eines de solutions physiologiques sur le comportement \'electrochimique du Ti-6Al-4V : reproductibilit\'e et repr\'esentation temps-fr\'equence
نویسندگان
چکیده
The electrochemical behaviour of the biomedical and metallic alloys, especially in the orthopaedic implants fields, raises many questions. This study is dedicated for studying the Ti6Al-4V alloy, by electrochemical impedance spectroscopy, EIS, in various physiological media,: Ringer solution, phosphate buffered solution (PBS), PBS solution and albumin, PBS solution with calf serum and PBS solution with calf serum and an antioxidant (sodium azide). Moreover, the desionised water was considered as the reference solution. The tests reproducibility was investigated. The time-frequency-Module graphs highlighted that the desionised water is the most protective for the Ti-6Al-4V alloy. This biomedical alloy is the less protected in the solution constituted by PBS and albumin. The time-frequency graph allows pointing out the graphic signatures of adsorption for organic and inorganic species (differences between the modules means in studied solution and the modules mean in the reference solution).
منابع مشابه
Experimental Evaluation of Surface Alterations Induced in Machining of Ti-6Al-4V Alloy
Surface integrity of workpieces after machining processes is one of the most essential requirements of engineers in advanced industries, since it has significant effect on performance and service life of the components. Based on this, thermal and mechanical loads generated by machining are responsible for change in mechanical properties of the machined workpiece and consequently, they should be...
متن کاملInvestigation of the effect of temperature on the corrosion behavior of welded joints similar of titanium alloy Ti-6Al-4V by friction stir welding method
In this study, corrosion behavior of Ti-6Al-4V titanium alloy joint by friction stir welding with a rotational speed of 375 rpm and a travel speed of 100 mm/min was investigated. The welding procedure was carried out under β-transus temperature that was consisted of equiaxed grains in the stir zone. The corrosion behavior of the welded joint was investigated in 3.5% NaCl solution at temperature...
متن کاملCorrosion behavior of pure titanium and titanium alloys in various concentrations of Acidulated Phosphate Fluoride (APF) solutions.
The corrosion behaviors of Ti, Ti-6Al-7Nb and Ti-6Al-4V alloys, and an experimentally produced Ti-0.5Pt alloy in 0.05% to 2.0% concentrations of Acidulated Phosphate Fluoride (APF) solutions (corresponding to 226 to 9,050 ppm fluoride at pH 3.5 or 3.6) were examined. While the corrosion of Ti, Ti-6Al-7Nb and Ti-6Al-4V alloys might occur easily even in a diluted 0.05% APF solution, dissolution o...
متن کاملOsteoblastic behavior to zirconium coating on Ti-6Al-4V alloy
PURPOSE The purpose of this study was to assess the surface characteristics and the biocompatibility of zirconium (Zr) coating on Ti-6Al-4V alloy surface by radio frequency (RF) magnetron sputtering method. MATERIALS AND METHODS The zirconium films were developed on Ti-6Al-4V discs using RF magnetron sputtering method. Surface profile, surface composition, surface roughness and surface energy...
متن کاملCorrosion behavior of pure titanium and titanium alloys in fluoride-containing solutions.
The effects of fluoride concentrations and pH on the corrosion behavior of pure titanium, Ti-6Al-4V, Ti-6Al-7Nb alloys and a new Ti alloy adding palladium, which is expected to promote a repassivation of Ti were examined by anodic polarization and corrosion potential measurements. The amount of dissolved Ti was analyzed by inductively coupled plasma mass spectroscopy. The surface of the specime...
متن کامل