Automated measurement of resolution acuity in infants using remote eye-tracking.
نویسندگان
چکیده
PURPOSE To validate a novel, automated test of infant resolution acuity based on remote eye-tracking. METHODS Infants aged 2 to 12 months were tested binocularly using a new adaptive computerized test of infant vision using eye tracking (ACTIVE), and Keeler infant acuity cards (KIAC). The ACTIVE test ran automatically, using remote eye-tracking to assess whether the infant fixated a black-and-white grating of variable spatial frequency. Test-retest reliability was assessed by performing each test twice. Accuracy was assessed by comparing acuity measures across tests and with established age-norms, and by comparing low-contrast acuity estimates in adults with data reported previously. RESULTS All infants completed the ACTIVE test at least once. Median test duration was 101 seconds. Measured visual acuity increased with age (P < 0.001), and 90% of mean acuity estimates were within previously published 90% tolerance limits (based on acuity-card age norms). Acuity estimates were also correlated, within-subjects, with results from the KIAC (P = 0.004). In terms of reliability, 86% of acuity estimates deviated by ≤1 octave, with no significant difference in test-retest reliability between the ACTIVE and KIAC procedures (P = 0.461). In adults, acuity estimates from the ACTIVE test did not differ significantly from values reported by previous authors (P > 0.183). CONCLUSIONS An adaptive computerized test of infant vision using eye-tracking provides a rapid, automated measure of resolution acuity in preverbal infants. The ACTIVE performed comparably to the current clinical gold standard (acuity cards) in terms of testability, reliability, and accuracy, and its principles can be extended to measure other visual functions.
منابع مشابه
Nonlinear Filtering Models of Attentive Vision
A nonlinear estimation problem motivated by attentive vision in the human visual system is considered. In human vision, eye and head motion are used to bring objects of interest into the high resolution foveal regions of the retina. Accurate estimates of target position are thereby attained in certain target tracking situations using sensors (eyes) having nonuniform and mostly low acuity. This ...
متن کاملSpatial resolution of conscious visual perception in infants.
Humans' conscious awareness of objects in their visual periphery is limited. This limit is not entirely the result of reduced visual acuity. Rather, it is primarily caused by crowding--the difficulty identifying an object when it is surrounded by clutter. The effect of crowding on visual awareness in infants has yet to be explored. Do infants, for example, have a fine-grained "spotlight," as ad...
متن کاملOMR-Arena: Automated Measurement and Stimulation System to Determine Mouse Visual Thresholds Based on Optomotor Responses
Measurement of the optomotor response is a common way to determine thresholds of the visual system in animals. Particularly in mice, it is frequently used to characterize the visual performance of different genetically modified strains or to test the effect of various drugs on visual performance. Several methods have been developed to facilitate the presentation of stimuli using computer screen...
متن کاملEye-Tracking Method’ Usage for Understanding the Cognitive Processes in Multimedia Learning
Introduction: Designing multimedia learning environments should consist of the evidence-based study and principals about the human learning process. Eye tracking is a way based on the learner processing of learning materials which presented in multimedia learning environments. The aim of the study was to examine the use of the eye-tracking method to investigate the cognitive processes in m...
متن کاملFeasibility Study of Real-time and Automated Monitoring of Iranian Rivers using 50-kHz Fluvial Acoustic Tomography System
Acoustic Tomography (AT) technique is an innovative method for real-time river monitoring. In this study, not only the accuracy of flow velocity measurement using 50 kHz AT system which is appropriate for narrow rivers (most Iranian rivers) is evaluated, but also its performance is compared with 30 kHz one which is used in wide rivers. The comparison results showed that the velocity resolutions...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 55 12 شماره
صفحات -
تاریخ انتشار 2014