Fixation to the canine bone of artificial implant with new surface structure.

نویسندگان

  • Takahiro Seno
  • Yasuharu Izumisawa
  • Ikuya Nishimura
  • Seiya Maehara
  • Tokiko Kushiro
  • Mohammed Ahmed Umar
  • Shinsuke Wakaiki
  • Kazuto Yamashita
  • Tadao Kotani
چکیده

Screw and laser (SL) column by making screw threads and forming small holes using laser irradiation on the base metal and conventional beads coating (BC) columns were embedded into the shaft of canine femurs, and compared the implant fixation to the host bone. The interfacial strength in SL columns was almost equivalent as BC columns, and bone-column contact rate was higher than BC columns significantly at twelve weeks after implantation. The newly devised SL surface had almost equivalent bone fixation strength comparable to the conventional BC surface. Also, this surface should provide a useful porous surface for use in artificial joints since there is no risk of surface structure detachment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mathematically and experimentally defined porous bone scaffold produced for bone substitute application

Objective (s): Artificial bone implants have been studied as a possible bone replacement for fractured and destroyed facial tissue; the techniques employed to determine the success of the dental implants. The stability, porosity and resistance of the bone implant which is subjected to varying forces and stresses within the surrounding bone is a subject of interest among the dentists. Materials ...

متن کامل

Adipose- Derived Stem Cells as a Tool for Dental Implant Osseointegration: an Experimental Study in the Dog

The biological interaction between the jaw bones and dental implant is fundamental for the long-term success of dental implant placement. Nevertheless, the insufficient bone volume remains a major clinical problem, especially in case of immediate dental implant. Using a canine model, the present study proves the regenerative potential of adipose- derived stem cells (ADSCs) to repair peri-implan...

متن کامل

Acid Etching and Plasma Sterilization Fail to Improve Osseointegration of Grit Blasted Titanium Implants

Interaction between implant surface and surrounding bone influences implant fixation. We attempted to improve the bone-implant interaction by 1) adding surface micro scale topography by acid etching, and 2) removing surface-adherent pro-inflammatory agents by plasma cleaning. Implant fixation was evaluated by implant osseointegration and biomechanical fixation.The study consisted of two paired ...

متن کامل

Interradicular Space in the Anterior Mandible on CBCT Scans of an Iranian Population

Abstract Background and Aim: This study aimed to assess the bone thickness at the interradicular spaces in the anterior mandible on cone-beam computed tomography (CBCT) scans of patients to find appropriate sites for mini-implant and miniscrew placement. Materials and Methods: This analytical cross-sectional study was conducted on 161 CBCT scans of patients (98 females and 63 male...

متن کامل

The Effect of Dual Acid Texturing Implants on Bone Ongrowth - an Unloaded Implant Model in an Experimental Canine Study

INTRODUCTION: Treatment of osteoarthritis and rheumatoid arthritis by total joint replacement generally shows a high success rate; however challenges remain, particularly in improving revision implant fixation. Prostheses with a roughened surface inserted without cement are popular worldwide, especially for younger more active patients. Early bone ongrowth is known to be critical to long-term f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of veterinary medical science

دوره 66 3  شماره 

صفحات  -

تاریخ انتشار 2004