Confocal microscopy with a volume holographic filter.
نویسندگان
چکیده
We describe a modified confocal microscope in which depth discrimination results from matched filtering by a volume hologram instead of a pinhole filter. The depth resolution depends on the numerical aperture of the objective lens and the thickness of the hologram, and the dynamic range is determined by the diffraction efficiency. We calculate the depth response of the volume holographic confocal microscope, verify it experimentally, and present the scanned image of a silicon wafer with microfabricated surface structures.
منابع مشابه
Confocal Imaging Through Scattering Media with a Volume Holographic Filter
The use of a volume holographic filter as collector element in a confocal system imaging through scattering (turbid) material is described. We show that the penetration depth of the volume holographic system is de-coupled from the scatter noise discrimination properties, and is potentially more advantageous than the traditional confocal microscope. Since the volume-holographic filter is a match...
متن کاملOptical Design for a Spatial-Spectral Volume Holographic Imaging System.
Spatial Spectral Holographic imaging system (S(2)-VHIS) is a promising alternative to confocal microscopy due to its capabilities to simultaneously image several sample depths with high resolution. However, the field of view of previously presented S(2)-VHIS prototypes has been restricted to less than 200μm. This paper presents experimental results of an improved S(2)-VHIS design which have a f...
متن کاملNon-axial-scanning multifocal confocal microscopy with volume holography
Wide-field fluorescence microscopy is a commonly used imaging technique by researchers and clinicians. A standard wide-field microscope has no optical sectioning capabilities and this limits its use in imaging thick biological samples. Although standard wide-field fluorescence microscopy with deconvolution techniques can improve image quality [1], it does not provide true optical sectioning, du...
متن کاملVariations of the Normal Human Limbal Stem Cells Detected by In Vivo Confocal Microscopy
Background To report normal variations of the limbal structures using in vivo laser scanning confocal microscopy. Methods: This was a retrospective study of fourteen eyes from 11 healthy individuals. Confocal imaging of cornea and limbus was performed using Heidelberg Retina Tomograph III Rostock Corneal Module. Results: The typical structure of the palisades of Vogt (POV) was detected ...
متن کاملPrintable ink holograms
Articles you may be interested in Multilayer stacking technique for holographic polymer dispersed liquid crystals Appl. Experimental verification of the applicability of the homogenization approximation to rough one-dimensional photonic crystals using a holographically fabricated reflection grating Experimental study of moiré method in laser scanning confocal microscopy Rev.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Optics letters
دوره 24 12 شماره
صفحات -
تاریخ انتشار 1999