NCPAP for the treatment of obstructive sleep apnea.

نویسندگان

  • A B Silva
  • H Lemmi
چکیده

Nasal continuous positive airway pressure (NCPAP) represents a real advance in the management of obstructive sleep apnea (OSA). Our data show that except for awakenings, all sleep and respiratory parameters were significantly improved (p less than 0.05) in favor of the group treated with NCPAP. A main problem with NCPAP is the acceptance by the patient; it also may disturb the sleep, at least, on short term basis and, in a small number of patients, it does not correct the apneas. In our patients series, males responded better to NCPAP than females.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hypoxemia vs sleep fragmentation as cause of excessive daytime sleepiness in obstructive sleep apnea.

To determine the effects of intermittent hypoxemia on daytime sleepiness in the clinical setting of obstructive sleep apnea syndrome, we enrolled seven patients in a prospective, randomized, crossover study. We had two experimental conditions with NCPAP treatment as follow: (1) to correct apneas, sleep fragmentation, and hypoxemia; and (2) to correct apneas and sleep fragmentation and at the sa...

متن کامل

Required levels of nasal continuous positive airway pressure during treatment of obstructive sleep apnoea.

The improvement in the severity of obstructive sleep-related breathing disorders during nasal continuous positive airway pressure (NCPAP) therapy can account for the decrease in the required NCPAP level with time. The aim of this study was to prospectively quantify the changes in the required NCPAP level over time of use in sleep apnoea-hypopnoea syndrome (SAHS). Forty sleep apnoea-hypopnoea pa...

متن کامل

Humidified nasal continuous positive airway pressure in obstructive sleep apnoea.

Heated humidification of nasal continuous positive airway pressure (nCPAP) reduces upper airway symptoms and improves initial use in obstructive sleep apnoea syndrome (OSAS). The present study aimed to assess the effect of heated humidification of nCPAP on upper airway symptoms and initial use in obstructive sleep apnoea. This study was of a randomised, crossover design. Subjects with polysomno...

متن کامل

Efficacy and cost of home-initiated auto-nCPAP versus conventional nCPAP.

STUDY OBJECTIVES To compare in a multicenter prospective study the efficacy and cost of conventional nasal continuous positive airway pressure (nCPAP) initiated at the sleep laboratory versus auto-nCPAP initiated at home. DESIGN Patients with severe obstructive sleep apnea syndrome (OSAS) were randomized to treatment with either the REM+ auto device in constant mode at the effective pressure ...

متن کامل

Effect of nasal continuous positive airway pressure treatment on blood pressure in patients with obstructive sleep apnea.

BACKGROUND There is increasing evidence that obstructive sleep apnea (OSA) is an independent risk factor for arterial hypertension. Because there are no controlled studies showing a substantial effect of nasal continuous positive airway pressure (nCPAP) therapy on hypertension in OSA, the impact of treatment on cardiovascular sequelae has been questioned altogether. Therefore, we studied the ef...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Arquivos de neuro-psiquiatria

دوره 47 2  شماره 

صفحات  -

تاریخ انتشار 1989