White Paper, GeneChip® 3 ' IVT Express Kit
ثبت نشده
چکیده
The GeneChip 3’ IVT Express Kit is the newest option for generating target for Affymetrix 3’ expression arrays. The 3’ IVT Express Kit utilizes the same basic chemistry as GeneChip One-Cycle Target Labeling and Control Reagents, but employs a simplified workflow and optimized reagents that enable lower RNA input and increased ease of use. In this white paper, we describe the technical performance of the 3’ IVT Express Kit and compare array results with One-Cycle Reagents. Introduction Affymetrix 3’ expression arrays have probe sets targeted to the 3’ end of the transcript. Target for these arrays is prepared using amplification and labeling methodologies that generate labeled target initially primed from the poly-A tail of the transcript. First-strand cDNA is synthesized using an oligo-dT primer with an attached T7 promoter sequence. After making the complementary second strand, the double-stranded cDNA molecule is amplified in a linear fashion by in vitro transcription (IVT) using T7 RNA polymerase. As the aRNA (amplified RNA, also commonly referred to as cRNA) is being made, a biotinylated nucleotide analog is incorporated and serves as a label for the message. After fragmentation, this labeled anti-sense aRNA is hybridized to the array. We have developed a new kit that utilizes this same basic strategy for generating target for hybridization to GeneChip 3’ expression arrays. The 3’ IVT Express Kit uses optimized reagents that dramatically reduce the total RNA input requirements. For most RNA types, 50 to 100 ng of total RNA will generate sufficient amounts of labeled target for the largest-format cartridge array. Because of the low total RNA input requirements, the 3’ IVT Express Kit is intended to replace the One-Cycle and Two-Cycle Target Labeling and Control Reagents. In addition, the 3’ IVT Express Kit provides a simplified workflow and includes pre-made master mixes that decrease hands-on time (see Figure 1). Those using higher input amounts (100 to 500 ng) can complete the target preparation protocol in a single day. Compared to One-Cycle Reagents, the cDNA cleanup step has been removed and all purification steps now use magnetic beads instead of spin columns for enhanced recovery. The kit contains all of the reagents needed to generate labeled aRNA target and also includes a control RNA sample, poly-A RNA and hybridization controls, and the plastic consumables needed to run the assay.
منابع مشابه
Screening for genes that are differentially-expressed between gastric cancer cells and gastric tumor sphere cells using the gene chip technique.
The purpose of this study was to screen for genes that were differentially expressed between a human gastric carcinoma cell line (HGC-27) and their tumor spheres, using the gene chip technique. The HGC-27 cells and tumor sphere cells were cultured in vitro in a sterile environment. Total RNA was extracted from both samples and purified using a standard TRIzol reagent. Total RNA was then hybridi...
متن کاملIndividual and System Contributions to Race and Sex Disparities in Thrombolysis Use for Stroke Patients in the United States.
BACKGROUND AND PURPOSE Intravenous thrombolysis (IVT) is underutilized in ethnic minorities and women. To disentangle individual and system-based factors determining disparities in IVT use, we investigated race/sex differences in IVT utilization among hospitals serving varying proportions of minority patients. METHODS Ischemic stroke admissions were identified from the Nationwide Inpatient Sa...
متن کاملComparison of target labeling methods for use with Affymetrix GeneChips
BACKGROUND Several different commercial one-cycle labeling kits are available for preparation of the target for use with the Affymetrix GeneChip platform. However, there have been no evaluations of these different kits to determine if comparable results were generated. We report on the cRNA target synthesis, labeling efficiency and hybridization results using the One-Cycle Target Labeling Assay...
متن کاملRelationship between optimal lactate removal power output and Olympic triathlon performance.
To investigate the relationships between race performance and parameters at the optimal power output for lactate removal, 10 male triathletes were examined. Exercise intensities for lactate removal were defined by calculating 50% of difference (DeltaT) between running velocity (V(r)) at individual anaerobic threshold (IAT) and at individual ventilatory threshold (IVT), then choosing 3 V(r): at ...
متن کاملCorrection: Various Blood Glucose Parameters that Indicate Hyperglycemia after Intravenous Thrombolysis in Acute Ischemic Stroke Could Predict Worse Outcome
BACKGROUND Hyperglycemia is common after stroke, and it is well known to worsen its outcome. However, it is important to consider that blood glucose (BG) levels can undergo dynamic changes during the acute stage of ischemic stroke. We sought to investigate the clinical significance of various glucose parameters within first 24 hours in acute ischemic stroke (AIS). The study focused on hyperacut...
متن کامل