Comparison of glomerular filtration rate measured between anterior and posterior image processing using Gates’ method in an ectopic pelvic kidney
نویسندگان
چکیده
OBJECTIVE The aim of this study was to evaluate the difference in measured glomerular filtration rate (GFR) of an ectopic pelvic kidney between anterior and posterior image processing using Gates' method of renal dynamic imaging. METHODS A total of 10 patients were studied retrospectively, with a single ectopic kidney in the pelvic cavity and a contralateral kidney at its normal anatomical position confirmed by ultrasound, computed tomography, renal dynamic imaging, etc. All images of ectopic kidneys were processed, and GFRs were measured using anterior and posterior Gates' method of renal dynamic imaging, respectively. The contralateral normal kidney was only processed on posterior imaging. The total GFRant of one patient, which was equal to the sum of the GFR of a normal kidney on posterior imaging and the GFR of an ectopic kidney on anterior imaging, was compared with the total GFRpost of two kidneys on posterior imaging, with the GFRtwo-sample from the two-sample method, and with the estimated GFR in the Chronic Kidney Disease Epidemiology Collaboration equation. All correlation analyses were carried out between GFRs obtained from three methods, and all patients were followed up. For statistical analysis, nonparametric rank tests were used, Bland-Altman graphs were plotted. RESULTS The mean GFR of the ectopic kidney on anterior imaging was 27.48±12.24 ml/min/1.73 m. It was higher than the GFR (10.71±4.74 ml/min/1.73 m) on posterior imaging (t=-2.803, P<0.05). There were statistical differences between the total GFRant and the total GFRtwo-sample (Z=-2.295, P<0.05), between the total GFRant and the total GFRpost (Z=2.599, P<0.01), between the total GFRtwo-sample and the total GFRpost (Z=-2.191, P<0.05), and between the total GFRant and the estimated glomerular filtration rate (Z=-2.803, P<0.01). The bias of the total GFRant was different from that of the total GFRpost (Z=-2.191, P<0.05). There were no differences in the precision and accuracy within 30% of the total GFRant and that of the total GFRpost (precision: F=0.351, P>0.05), but there were statistical differences in the accuracy within 10% of the total GFRant and that of the total GFRpost (P<0.05). CONCLUSION The GFR measured using Gates' method of anterior image processing was more accurate than the GFR obtained on posterior image processing in reflecting the function of an ectopic pelvic kidney in renal dynamic imaging.
منابع مشابه
Quantitative and Qualitative Scintigraphic Measurement of Renal Function in Persian Cat Using 99mTechnetium Ethylenedicysteine and 99mTechnetium Diethylenetriaminepentaacetic
Objective- To consider the use of renal scintigraphic evaluation of kidney function in Persian cat and make a comparison between 99mTechnetium ethylenedicysteine and 99mTechnetium diethylenetriaminepentaacetic in renal scintigraphy. Design- Descriptive study Animals- 6 male healthy adult Persian cats - no clinical sign of renal disorders and prior to presentation. Proce...
متن کاملEvaluation of Glomerular Filtration Rate Estimating Formulas in Diabetic Patients with Chronic Kidney Disease
Objective: Measurement of glomerular filtration rate (GFR) is the best determinant in assessment of kidney function for diagnostic and therapeutic purposes. As extremely accurate methods of GFR measurement (i.e. Inulin clearance) are expensive and Time-consuming and due to limitations of the 24 hour urine collection method, some formula have been developed for the GFR measurement. Here we have ...
متن کاملDetermining an accurate method to estimate GFR in renal transplant recipients with stable serum creatinine levels
Introduction:Detecting renal allograft dysfunction early will allow timely diagnosis and treatment. There is no objective recommendation by national kidney societies for glomerular filtration rate (eGFR) estimation in post-transplant setting. 99mTc-DTPA Technetium-99m Diethylene triamine penta acetic acid) renogram can identify early renal dysfunction much before ser...
متن کاملComparison of Serum Cystatin C and Creati-nine Levels to Evaluate Early Renal Function after Kidney Transplantation
Background: Accurate and rapid assessment of allograft function is essential in renal transplant recipients in order to detect allograft rejection and to monitor drug nephrotoxicity. We aimed to evaluate the usefulness of cystatin C as a marker of kidney allograft function in the early post-transplant period and to compare this value with that of conventional serum creatinine concentration. Met...
متن کاملComparison of glomerular filtration rate measurements with the two-plasma sample technique using Tc-99m DTPA and other methods in donor candidates for renal transplantation.
BACKGROUND/AIM Accurate measurement of glomerular filtration rate (GFR) in the evaluation of renal functions in potential kidney donors is associated with important outcomes for both the donor and recipient. We intended to determine the efficacy of various methods while estimating GFR in potential living kidney donors. MATERIALS AND METHODS Fifty-three potential kidney donors (31 females, 22 ...
متن کامل