Imaging and evaluation of coronary artery bypass graft patency by 16-slice multidetector computed tomography.
نویسندگان
چکیده
INTRODUCTION The purpose of this study was to evaluate the patency of coronary artery bypass grafts (CABGs) while assessing the capabilities and limitations of 16-slice multidetector computed tomography. METHODS We studied retrospectively 19 patients (13 men, 6 women), over an 18-month period. All patients had undergone CABG surgery 3 months to 7 years earlier. Two patients were examined on an emergency basis for chest pain and their CABGs were evaluated simultaneously. The number of CABGs in each patient ranged from one to three. A total of 44 grafts were assessed. All scans were performed by a 16-row multislice scanner (Toshiba Aquilion). Maximum intensity projections, multiplanar reformations, and volume rendering techniques were performed on a Vitrea workstation. All 19 patients also underwent invasive catheter coronary angiography for confirmation of their status. RESULTS Of the 44 grafts evaluated, 26 were classified as patent, 13 as not patent, and 5 as stenotic. In the bypass grafts with stenosis > or = 50% there was a difference in the mean level of enhancement before and after the stenosis (265.38 +/- 35.82 and 178.56 +/- 9.32, respectively). Seventeen arterial and 27 venous grafts were imaged. Of the 13 non-patent grafts, 8 were venous. In 3 cases of arterial grafts the distal anastomoses were not delineated. The assessment of venous grafts was easier because of their larger diameter and lack of surrounding clips. One case of a carotid-subclavian shunt with a distal anastomosis of the left internal mammary artery to the left anterior descending branch was reported. Sensitivity, specificity, positive and negative predictive values for stenosis were evaluated. CONCLUSIONS Multidetector computed tomography is a fast and non-invasive modality for evaluating CABG patency that is gaining acceptance as an alternative method to invasive coronary angiography. Sensitivity and specificity are determined by the available and evolving technology.
منابع مشابه
Non-invasive assessment of coronary artery bypass graft patency using 16-slice computed tomography angiography
BACKGROUND Invasive coronary angiography is the gold standard means of imaging bypass vessels and carries a small but potentially serious risk of local vascular complications, including myocardial infarction, stroke and death. We evaluated computed tomography as a non-invasive means of assessing graft patency. METHODS Fifty patients with previous coronary artery bypass surgery who were listed...
متن کاملRationale, design and methodology for a Prospective Randomized Study of graft patency in Off-pump and On-pump MultI-Vessel coronary artery bypasS Surgery (PROMISS) using multidetector computed tomography
BACKGROUND Off-pump coronary artery bypass grafting has been accused of possibly compromising graft patency. Sixteen slice computed tomography has shown good diagnostic accuracy in the assessment of coronary bypass graft patency when compared with conventional coronary artery angiography and is less invasive. The study hypothesis is that coronary artery bypass grafting (CABG) performed without ...
متن کاملNoninvasive evaluation of coronary artery bypass grafts and native coronary arteries: is 16-slice multidetector CT useful?
PURPOSE To investigate the diagnostic accuracy and limitations of 16-slice multidetector computed tomography (MDCT) in the detection of significant ( > 50%) stenosis of coronary artery bypass grafts (CABG) and native coronary arteries. MATERIALS AND METHODS One hundred two patients with 236 grafts were investigated by 16-slice MDCT. Native coronary arteries were also investigated. The image q...
متن کاملEarly patency evaluation of new distal anastomotic device in internal mammary artery grafts using computed tomography angiography.
INTRODUCTION : Traditional coronary artery bypass grafting is performed using a hand sewn technique. The C-Port xA and Flex A anastomotic stapling devices (Cardica Inc., Redwood City, CA) were cleared by the Food and Drug Administration for use in distal coronary anastomoses in November 2006 and April 2007, respectively. They provide the ability to create a compliant, consistently reproducible,...
متن کاملProspective evaluation of patency and early experience utilizing an automated distal anastomosis device (C-port).
BACKGROUND : In November 2005, a new automated distal anastomotic device (C-Port) for coronary artery bypass grafting (CABG) was cleared by the FDA for use in the United States. This study represents a prospective evaluation of our early experience using the device with graft patency assessment determined by 64 slice multidetector row computed tomography angiography (64CT). MATERIALS AND METH...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Hellenic journal of cardiology : HJC = Hellenike kardiologike epitheorese
دوره 48 5 شماره
صفحات -
تاریخ انتشار 2007