High Resolution Magnetization Transfer Imaging at 3T VS. 1.5T

نویسندگان

  • Y. Wu
  • C. O'Brien
  • C. Glielmi
  • H. Du
  • R. Edelman
چکیده

INTRODUCTION: While most clinical studies using magnetization transfer (MT) imaging have been performed at 1.5T, high resolution-MT imaging (hr-MT) is feasible at 3T. Higher field enables efficient acquisition with improved conspicuity of brain structures (1). Hr-MT has considerable potential for investigating neurological disorders affecting small brain structures such as early stage Alzheimer’s disease. Before implementing hr-MT in a patient population, it is critical to optimize scan parameters, assess the reliability and establish a quality assurance procedure at 3T. This investigation takes a two-fold approach to systematically optimize and compare scan parameters at 1.5 and 3T. First, phantom experiments optimize signal-to-noise ratio (SNR), MT ratio (MTR) and repeatability. Second, human studies evaluate acquisition parameters to study regions of clinical interest, such as the hippocampus, and support findings with simulations to maximize MTR contrast between brain tissue types. METHOD AND MATERIALS: Image Acquisition: All hr-MT scans were performed on 1.5 and 3T scanners (MAGNETOM Avanto and Verio, Siemens Healthcare, Erlangen, Germany). Phantom Scans: An agar phantom was constructed of six tubes with varying concentrations of homogeneous agar gel (0.5%, 1%, 1.5%, 2%, 2.5%, 5%) submerged in a sealed water-filled cylinder and used to optimize the hr-MT protocol using a range of flip angles (FA), voxel sizes and correction for pulsation artifacts. To assess reliability, hr-MT measurements were obtained at three different times at both 3T and 1.5T. MT parameters were: MT-1 (TR/TE/FA of 37 ms/4ms/10°; spatial saturation, 10 mm inferior to the 50 mm 3D acquisition slab); MT-2 (TR/TE/FA 30 ms/4 ms/10°); MT-3 (TR/TE/FA 30 ms/5.45 ms/5°). All scans used MT FA of 500 degrees. MT-1 and MT-2 both used a fast GRE pulse, while MT-3 used normal a GRE pulse. The spatial resolution was 1x1x1.2 mm for MT-1 and MT-2, and 1.3x1x2 mm for MT-3. MT preparation consisted of a Gaussian shape saturation pulse (with and without MT) at 1200 Hz and 1500 Hz offset from water resonance for 3T and 1.5 T, respectively. Human Scans: Eight healthy volunteers (7 male, 1 female. Age: Mean ± SD: 37 ±17.22; range 22 to 60) were scanned twice one week apart at 3T (90 axial slices with whole brain coverage using MT-1 and MT-2). These images were compared to MT images obtained with 3D GRE human scans at 1.5T (TR/TE/FA 19 ms/4 ms/25°, spatial resolution = 1x1x1.3 mm). Image Analysis: MTR values were estimated using standard equations on a Linux workstation for the human brain images and phantom data were analyzed on a LEONARDO workstation (Siemens, Germany). On brain images, an operator manually placed regions of interest (ROIs) to obtain the Mean and SD of signal intensity in genu, splenium, hippocampus (R, L), caudate (R,L), putamen (R, L) and thalamus (R, L). An operator obtained MTR for different concentrations of agar gel tubes on the phantom images. Quantitative Evaluation: Apparent SNR was estimated for data collected at 1.5T and 3T. To simulate relative white matter / gray matter ratio, relative contrast ratio based on the mean signal intensity of the 5% (SI5%) and 2.5% (SI2.5%) was computed using the following equation: Relative contrast ratio 5% / 2.5% = (SI5%– SI2.5%) / SI2.5%. Statistical Analysis: Statistical methods included analysis of variance for repeated measures, independent t-tests, paired t-tests and Spearman intra-class correlation coefficients (ICC). All statistical tests were executed with SAS 9.1 by using a significance level of 0.05. RESULTS: The apparent SNR at 3T was 1.44 ~ 3.44 fold that of 1.5T (Table 1), while maintaining similar MTR values (Figure 2) and relative contrast ratios (data not shown). MT-2 had the highest apparent SNR in the phantom study (Table 1); however, MT-2 brain images showed hippocampal pulsation artifacts. MT-1 compensated for pulsation artifacts, but apparent SNR in the phantom study was significantly lower than that of MT-2 (p<.0001) likely caused by image degradation from the saturation band. While MTR is negatively correlated with FA (rs: -0.667, p<.0001), SNR is positively correlated with FA (rs: 0.454, p=0.0003). Therefore, MT-3 offers the best balance of SNR with minimized artifacts. Figure 2 shows that repeated measurements at 3T generated similar or more consistent MTR values over time relative to 1.5T for phantom scans (Table 2). For the human scans at 3T, much higher reproducibility of MTR was obtained for MT-2 compared with MT-1 (Table 3). Excellent reproducibility of MTR in hippocampus were obtained (ICC: 0.86 ~ 0.91). CONCLUSION: Phantom scans were effective in sequence optimization and served as the foundation for human studies and comparison across field strengths. At 3T the increased field strength significantly improved image quality, as indicated by the increase in apparent SNR compared with 1.5T. While potentially increased scan variation at higher field is a concern, this investigation suggests that 3T studies provide more consistent MTR measurement over time relative to 1.5T, overall the reproducibility were very high for both 1.5T and 3T. This study combines phantom and human data to optimize parameters and improve reliability at 3T relative to 1.5T. These findings serve as a precursor to transition for 3T clinical studies requiring high spatial resolution and repeated measurements over time. Importantly, our findings in the human study indicate excellent reproducibility in regions such as the hippocampus that are critical regions for detecting early changes in Alzheimer’s disease and other neurological disorders. Our results demonstrate the promising potential of high resolution MT for clinical application. REFERENCES: 1. Gringel et al. JRMI. 2009 Jun;29(6):1285-92.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative Magnetization Transfer Imaging of Human Cervical Spinal Cord at 3T

Introduction: The goal of this study was to determine the feasibility of performing quantitative magnetization transfer (qMT) at high resolution in the spinal cord on clinical 3T systems. While magnetization transfer (MT) imaging has been used to assess brain tissue microstructure, similar studies in the human spinal cord have been limited. This can largely be attributed to the difficulties ass...

متن کامل

Real-time cardiac MRI at 3 tesla.

Real-time cardiac and coronary MRI at 1.5T is relatively "signal starved" and the 3T platform is attractive for its immediate factor of two increase in magnetization. Cardiac imaging at 3T, however, is both subtly and significantly different from imaging at 1.5T because of increased susceptibility artifacts, differences in tissue relaxation, and RF homogeneity issues. New RF excitation and puls...

متن کامل

Quantitative contrast ratio comparison between T1 (TSE at 1.5T, FLAIR at 3T), magnetization prepared rapid gradient echo and subtraction imaging at 1.5T and 3T.

INTRODUCTION Creating contrast between normal anatomy and pathology is the main goal of imaging. Here we compare contrast ratios of enhancing brain lesions at 1.5T between T1 TSE, magnetization prepared rapid gradient echo (MPRAGE) and subtraction and at 3T between T1 FLAIR, MPRAGE and subtraction. METHODS Contrast ratio between enhancing lesions and normal contralateral brain was measured fo...

متن کامل

High-resolution 3D-constructive interference in steady-state MR imaging and 3D time-of-flight MR angiography in neurovascular compression: a comparison between 3T and 1.5T.

BACKGROUND AND PURPOSE High-resolution MR imaging is useful for diagnosis and preoperative planning in patients with NVC. Because high-field MR imaging promises higher SNR and resolution, the aim of this study was to determine the value of high-resolution 3D-CISS and 3D-TOF MRA at 3T compared with 1.5T in patients with NVC. MATERIALS AND METHODS Forty-seven patients with NVC, trigeminal neura...

متن کامل

Analysis of Magnetization Transfer Ratio Measurements at 3T Using Multiple-Acquisition Balanced SSFP

Introduction. Magnetization transfer (MT) has become an important tool to study various tissue abnormalities, such as demyelination in brain white matter [1]. Recently, it has been shown that fast MT scans based on balanced steady-state free precession (bSSFP) with RF pulse modification achieve high SNR and high reproducibility at 1.5T [2]. At 3T, combination of multiple, phase-cycled, bSSFP sc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009