Simultaneous measurement of cardiac output by thermodilution, thoracic electrical bioimpedance and Doppler ultrasound.
نویسندگان
چکیده
To evaluate the accuracy of two non-invasive techniques for cardiac output (CO) measurement, we have measured CO simultaneously by thoracic electrical bioimpedance (TEB), pulsed Doppler ultrasound (DU) and standard thermodilution methods (TD) under different clinical conditions. Measurements were made in 10 patients: (I) during steady state anaesthesia with controlled IPPV ventilation (n = 131), spread over the entire ventilatory cycle; (II) during apnoea (n = 56); (III) during spontaneous breathing (n = 152) in the intensive care unit. Mean (SD) cardiac output values were: (I) COTD 3.5 (1.0) litre min-1, COTEB 3.4 (0.7) litre min-1, CODU 2.8 (0.7) litre min-1; (II) COTD 3.6 (0.6) litre min-1, COTEB 3.5 (0.4) litre min-1, CODU 2.9 (0.7) litre min-1; (III) COTD 7.7 (1.5) litre min-1, COTEB 7.6 (1.9) litre min-1, CODU 5.2 (1.4) litre min-1. The mean percentage deviation of TEB from TD ranged from -2.2% to 1.4% and that of DU from TD was from -16% to -32%. There were no statistically significant differences between TD and TEB, but TD and DU differed significantly during IPPV, apnoea and spontaneous ventilation (P < 0.0001).
منابع مشابه
Accuracy and Reliability of Non-invasive Cardiac Output: The Future in Cardiology?
A new generation of non-invasive cardiac output monitors provides an alternative to using conventional invasive methods such as thermodilution and direct Fick. The Bioz.com measures changes in thoracic electrical bioimpedance (TEB) of the descending aorta. The Innocor uses the principle of inert gas rebreathing. Simultaneous TEB and thermodilution cardiac output measurements were taken from 27 ...
متن کاملNon-invasive determination of cardiac output by Doppler echocardiography and electrical bioimpedance.
Cardiac output measured by thermodilution in 25 patients within 24 hours of acute myocardial infarction was compared with cardiac output measured by Doppler echocardiography (24 patients) and electrical bioimpedance (25 patients). The mean (range) cardiac outputs measured by Doppler (4.03 (2.2-6.0) 1/min) and electrical bioimpedance (3.79 (1.1-6.2) 1/min) were similar to the mean thermodilution...
متن کاملNon-invasive measurement of cardiac output by thoracic electrical bioimpedance: a study of reproducibility and comparison with thermodilution.
The performance and reproducibility of the BoMED NCCOM3 thoracic electrical bioimpedance cardiograph (TEB) has been evaluated in volunteers and patients. In resting supine volunteers, we determined the coefficient of variability over short time periods (30 min) and over several days, and examined the effects of differences in electrode type and electrode placement. The mean (range) intra-subjec...
متن کاملLack of agreement between bioimpedance and continuous thermodilution measurement of cardiac output in intensive care unit patients
BACKGROUND: Bolus thermodilution is the standard bedside method of cardiac output measurement in the intensive care unit (ICU). The Baxter Vigilance monitor uses a modified thermodilution pulmonary artery catheter with a thermal filament to give a continuous read-out of cardiac output. This has been shown to correlate very well with both the 'gold standard' dye dilution method and the bolus the...
متن کاملAccuracy, Precision, and Trending Ability of Electrical Cardiometry Cardiac Index versus Continuous Pulmonary Artery Thermodilution Method: A Prospective, Observational Study
Introduction Evaluation of accuracy, precision, and trending ability of cardiac index (CI) measurements using the Aesculon™ bioimpedance electrical cardiometry (Aesc) compared to the continuous pulmonary artery thermodilution catheter (PAC) technique before, during, and after cardiac surgery. Methods A prospective observational study with fifty patients with ASA 3-4. At six time points (T), m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of anaesthesia
دوره 72 1 شماره
صفحات -
تاریخ انتشار 1994